 13   

Precautions 

 

The thermometer includes a monitor battery. 

 

Refer to "Replacing the battery" before a measurement, open the battery cover and install the battery. 
When installing the battery, a current temperature is displayed. 
The accessory battery is for an operation monitor and may be short battery life. 

 

Replacing The Battery 

 

A coin battery (LR44) is used. When displaying faint characters, replace the battery as follows: 

1.  Turn over the AD-5625. Turn the battery cover in a 

counterclockwise and remove it. 

 
2.  Remove an old battery. 
 
3.  Install the battery so that its plus side (

+

, flat side) 

is upper face. 

 
4.  Reattach the battery cover and turn it in clockwise. 
 

Caution 

  Be sure to face the + side up when installing a battery. 
  Use the specified battery (LR44) only. 
  Do not disassemble, heat, short-circuit, dispose of in fire or attempt to recharge the battery. It may explode or 

leak and cause personal injury. 

  Keep the battery out of the reach of children. If swallowed, consult a physician immediately. 
  Follow the local regulations when disposing of a used battery. 
  To keep the thermometer watertight, do not damage the rubber ring or remove it from the battery compartment. 

 

Display Mode 

The thermometer has three display modes. 

Displaying mode 

Display example 

  Current temperature mode 

Displays the current temperature. 

 

 

 

The maximum temperature

 

 

 

  The maximum / minimum temperature mode 

Displays the latest maximum and minimum temperatures that are 
automatically stored in the thermometer. 

The minimum temperature 

 

 

 

  Automatic power-off function 

Turns the power off automatically after six or seven minutes of no 
operation. 

 AUTO

 

 

 
 

Step 1. 

Ex.: a coin. 

Rotate the battery cover. 

Step 3. 
New battery (LR44). 

Battery cover 

Purchase at www.scaleman.com

Summary of Contents for AD-1654

Page 1: ...DENSITY DETERNIMATION KIT HR AZ series HR A series F Z i s e r i e s F X i s e r i e s 1WMPD4002606 Purchase at www scaleman com...

Page 2: ...lt in minor or moderate injury Note Provides information useful for the user to operate the instrument This is a hazard alert mark Note This manual is subject to change without notice at any time to i...

Page 3: ...Volume Of Float 4 4 3 Temperature Of Liquid 4 4 4 Influence Of Wire 5 4 5 Surface Tension 5 4 6 Bubbles 5 5 Measuring The Density Of A Solid 6 5 1 Assembling The Kit HR AZ HR A Series 6 5 2 Assemblin...

Page 4: ...Ex strong acid strong alkali solution After using the density determination kit clean all surfaces to remove rust and oxides A balance is a precision instrument Avoid shocks and excessive loads Maint...

Page 5: ...e A body immersed in a liquid or a gas is subject to an upward force equal to the weight of the liquid or the gas it displaces The upward force is buoyancy 3 4 Density Of A Solid The density of a soli...

Page 6: ...hen measurement accuracy to the third decimal place or beyond is necessary measure the volume of the float using distilled water A B d 0 0035 d V Volume of float cm3 A Mass of float in air g B Mass of...

Page 7: ...that it is negligible 4 5 Surface Tension In solid density measurement a force surface tension of about 5 mg is exerted on the pan between the wire diameter of 1 mm of the density pan and the liquid s...

Page 8: ...ace the density pan on the density pan stand 8 Adjust the amount of the liquid so that the sample when placed on the lower pan in the liquid is about 10 mm below the surface of the liquid 9 When the v...

Page 9: ...ty such as distilled water into the beaker and place the beaker on the beaker stand 7 Place the density pan on the density pan stand 8 Adjust the amount of the liquid so that the sample when placed on...

Page 10: ...368 0 99333 0 99297 0 99259 40 0 99222 0 99183 0 99144 0 99104 0 99063 0 99021 0 98979 0 98936 0 98893 0 98849 50 0 98804 0 98758 0 98712 0 98665 0 98618 0 98570 0 98521 0 98471 0 98422 0 98371 60 0 9...

Page 11: ...t of sample in air in liquid 8 06 g cm3 Calculated Value A Weight of sample in air g 4 8102 g Value B Weight of sample in air Weight of sample in liquid g 0 5946 g Temperature of liquid C 26 C Density...

Page 12: ...ement Example of the assembled HR AZ series 6 2 Measuring The Density Of A Liquid Use the following procedure to obtain the density of a liquid 1 With the float hanging press the RE ZERO key to set th...

Page 13: ...on the sample surface and a measurement error occurs What can I do about this Tap water contains dissolved gases such as oxygen and carbon dioxide When tap water is used the released dissolved gases...

Page 14: ...nd into extreme high temperature and low temperature The AD 5625 has case of double structure can prevent from invading water Features The features of the AD 5625 is as follows Waterproof class is IPX...

Page 15: ...t disassemble heat short circuit dispose of in fire or attempt to recharge the battery It may explode or leak and cause personal injury Keep the battery out of the reach of children If swallowed consu...

Page 16: ...the current temperature are displayed in order when pressing the MAX MIN button Reset the memory of the maximum and minimum temperature before the measurement when using the maximum and minimum tempe...

Page 17: ...eaning The Thermometer With Water The thermometer is water resistant type When cleaning heavy dirt clean the thermometer with a cloth moistened with water and a mild detergent softly Specifications Se...