UNPACKING THE I/O SIGNAL CONDITIONER

a.1

Inspect Package for External Damage

Your 

I/O

Signal Conditioner was carefully packed in a sturdy cardboard

carton, with anti-static cushioning materials to withstand shipping shock.
Upon receipt, inspect the package for possible external damage. In case
of external damage to the package contact the shipping company imme-
diately.

a.2

Unpack the I/O Signal Conditioner

Open the carton carefully from the top and inspect for any sign of con-
cealed shipping damage. In addition to contacting the shipping carrier
please forward a copy of any damage report to your distributor or Aalborg
directly.

When unpacking the instrument please make sure that you have all the
items indicated on the Packing List. Please report any shortages promptly.

a.3

Returning Merchandise for Repair

Please contact the customer service representative of your distributor or
Aalborg if you purchased your 

I/O

directly, and request a 

Return

Authorization Number (RAN). Equipment returned without an RAN
will not be accepted. 

Aalborg reserves the right to charge a fee to the

customer for equipment returned under warranty claims if the instruments
are tested to be free from warrantied defects.

Shipping charges are borne by the customer. Items returned "collect"
will not be accepted!

It is mandatory that any equipment returned for servicing be purged and
neutralized of any dangerous contents including but not limited to toxic,
bacterially infectious, corrosive or radioactive substances. No work shall
be performed on a returned product unless the customer submits a fully
executed, signed SAFETY CERTIFICATE. Please request form from the
Service Manager. 

1

Summary of Contents for i/o 232

Page 1: ...COMMUNICATIONS TERMINALS OPERATING MANUAL I O SIGNAL CONDITIONER Technical Data Sheet No TD9809M Rev F Date of Issue December 9 2009 7 77172 727 132 844 278 03 48 473 204 51 73 343 384 55 89 843 206...

Page 2: ...E Compliance e ELECTRICAL CONNECTIONS e 1 Connector Pin Assignments e 2 Jumper Assignments f PROGRAMMING g CALIBRATION PROCEDURES g 1 Equipment Required for Calibration g 2 Calibration h SELECTING THE...

Page 3: ...ing List Please report any shortages promptly a 3 Returning Merchandise for Repair Please contact the customer service representative of your distributor or Aalborg if you purchased your I O directly...

Page 4: ...s See Selecting the Operating Mode d SPECIFICATIONS d 1 General Attributes INPUT AND OUTPUT ANALOG RANGE 0 5 Vdc or 4 20 mA jumpers selectable INPUT OVERVOLTAGE OVERCORRECT PROTECTION 15 Vdc 50 mA MIN...

Page 5: ...n allowing the stripped wire to be inserted Remove the screwdriver and the connection is made Pin 1 Analog input from sensor IN Pin 2 Analog input from sensor IN Pin 3 Analog output to sensor OUT Pin...

Page 6: ...A mode f PROGRAMMING Programming the module allows the user to set the communications baud rate module address and whether to use error checking Note that the address is included only for compatibilit...

Page 7: ...Equipment Required for Calibration You will need a 3 1 2 digit DMM set to the selected analog output range see Selecting Operating Mode a power supply and a dumb terminal or PC running a communication...

Page 8: ...alog output crc optional error checking characters the crc is composed of two ASCII characters CR ASCII carriage return character There are no spaces in the transmitted command spaces are inserted her...

Page 9: ...mmand M x crc CR The reply format is Bad Command crc CR If the command is not received no response is sent Host T Command T or t This command tells the I O Module to transmit its current reading Up to...

Page 10: ...nd understood The reply format is OK crc CR Host C Command C or c This command tells the I O Module to enter calibration mode Calibration instructions are sent to the terminal display See Calibrating...

Page 11: ...tly Is the power supply correctly selected according to requirements When several meters are used a power supply with appropriate current rating should be selected Were the connector pinouts matched p...

Page 12: ...10 APPENDIX 1 Components Diagram NOTE Aalborg7 reserves the right to change designs and dimensions at its sole discretion at any time without notice For certified dimensions please contact Aalborg7...

Page 13: ...OTE Aalborg7 reserves the right to change designs and dimensions at its sole discretion at any time without notice For certified dimensions please contact Aalborg7 3 000 76 2 4 166 105 8 1 750 44 5 1...

Page 14: ...2 6 1 GFM HOST PC RS232 PORT Fig 1 Connection diagram GFM to I O232 5 9 4 8 3 7 2 6 1 COMMON 10 30 VDC RX TX OUT OUT IN IN 8 7 6 5 4 3 2 1 SIGNAL CONDITIONER 8 15 7 14 6 13 5 12 4 11 3 10 2 9 1 5 9 4...

Page 15: ...the liability of Aalborg and the provisions of this warranty Defective products will be repaired or replaced solely at the discretion of Aalborg at no charge Shipping charges are borne by the custome...

Reviews: