RotoClone LVN
© 2015 American Air Filter Company, Inc. Any use of the text or images
this document contains, without permission of American Air Filter
Company, Inc., is prohibited. RotoClone, AAF, REDClean, REDFiltration,
and Reliable Efficient Durable are registered trademarks of American Air
Filter Company, Inc. d/b/a AAF International.
2.4
Electrical hazards
Before doing any work on the AAF equipment make sure that all potential
electrical hazards have been identified and that all electric current connected to
the equipment, and to any connected or associated equipment, has been properly
disconnected and securely locked-out to prevent accidental reconnection prior to
completion of the work. All electrical work shall be done in full accordance with the
current edition of NFPA 70, the National Electrical Code, and all other applicable
laws, rules, and regulations. All electrical work shall be performed by a licensed
electrician. Only original AAF parts shall be used as replacements for ongoing
maintenance and repair.
2.5
Rotating equipment
The RotoClone LVN will operate with a fan which is installed either on the
ground or on the top of the dust collector. The fan wheel rotates at a nominal
speed of 3,600 rpm and has the potential to cause severe injury. The fan wheel
could be accessed from inside the cabinet through the air inlet if the moisture
eliminator is removed, and from outside the cabinet through the fan discharge. All
due care should be exercised to avoid any contact with the operating fan. Under
no circumstances should the fan ever be allowed to operate when any of the
access panels on the dust collector, or the silencer, have been removed. The fan
must be disconnected and locked out prior to the performance of any maintenance
work, see paragraph 2.4.
2.6
Safety guards
The dust collector cabinet prevents access to the fan inlet. All access panels
shall remain bolted in place while the fan is operating. Prior to the removal of any
access panel the electrical power to the collector shall be disconnected and locked
out, see paragraphs 2.4 and 2.5. After electrical power is disconnected the fan
wheel will continue to rotate for a period of time before coasting to a stop. Do not
access the fan until the fan wheel has come to a complete stop.
3
GENERAL PRODUCT INFORMATION
3.1
Description
The RotoClone LVN is a complete dust control unit. Designed to perform its
various functions automatically, the RotoClone requires very little maintenance.
Like any other mechanical equipment, however, it should have regular attention
and be operated according to instructions to insure long life and trouble-free
service.