The unit out of level.
Corrosion or abrasion to impeller sections.
Material buildup inside collector.
13.3
Water entrainment in exhaust discharge
Buildup of water in the fan plenum. There is a drain hole near the front of
the fan discharge.
Excessive air flow through RotoClone. To stop entrainment caused by
excessive air flow, increase static pressure by partially closing the outlet slide
damper located on top of the RotoClone.
Surging of the RotoClone is a rocking of the water from end to end in the
unit. This can be caused by running the unit well below its rated capacity or too
high an external pressure resistance. Contact your local AAF sales representative
for assistance.
Material buildup on mist eliminator baffles.
14
RECOMMENDED SPARE PARTS LIST
Parts of the RotoClone will not require frequent replacement and spare part
stock is seldom necessary.
When ordering any parts, give RotoClone size, type and serial number.