background image

N e t wo r k   A p p l i a n c e      

F W S - 7 2 5 0  

 

Chapter 3 AMI BIOS Setup   

3-24 

Setup submenu: Chipset 

 

Summary of Contents for FWS-7250

Page 1: ...5 0 FWS 7250 1U Rackmount Network Appliance Platform Internal 2 5 SATA HDD x1 or 3 5 SATA HDD x 1 or 2 5 SATA HDD x 2 CF SATA Socket 4 LAN Ports 2 USB2 0 1 COM for Console 1 MiniCard Slot FWS 7250 Man...

Page 2: ...his manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any in fringements upon the rights of third parties that may result fr...

Page 3: ...spective owners Intel and Atom are trademarks of Intel Corporation AMI is a trademark of American Megatrends Inc CompactFlash is a trademark of the Compact Flash Association Microsoft Windows is a reg...

Page 4: ...FWS 7250 Gift Box Including Console Cable Ear Brackets If any of these items should be missing or damaged please contact your distributor or sales representative immediately Note VGA Cable is an optio...

Page 5: ...rd 2 3 2 3 Mechanical Drawing of Main Board 2 5 2 4 List of Jumpers 2 7 2 5 List of Connectors 2 7 2 6 Setting Jumpers 2 9 2 7 Auto Power Button JP1 2 10 2 8 CF Power Selection CN13 2 10 2 9 CMOS Sett...

Page 6: ...ector CN22 2 25 2 26 Giga LAN Port Connector CN23 2 26 2 27 Giga LAN Port Connector CN24 2 26 2 28 Giga LAN Port Connector CN25 2 27 2 29 COM Port Connector COM1 2 28 2 30 4 pin Fan Connector CPU_FAN1...

Page 7: ...Network Appliance F W S 7 2 5 0 vi Appendix A Programming the Watchdog Timer A 1 Watchdog Timer Initial Program A 2...

Page 8: ...Network Appliance F W S 7 2 5 0 Chapter 1 General Information 1 1 General Information Chapter 1...

Page 9: ...fits nicely into a space limited environment This compact FWS 7250 can be equipped with one 3 5 2 5 SATA HDD and CF SATA socket or two 2 5 SATA HDD In addition it offers flexible expansion with netwo...

Page 10: ...liance Intel Atom E3845 up to 1 91 GHz or Celeron J1900 up to 2 42 GHz Two 204 pin Dual Channel DDR3L 1333MHz SODIMM Up to 8GB Intel I210AT 10 100 1000Base TX Ethernet Port x 4 Internal 2 5 SATA HDD x...

Page 11: ...91 GHz Celeron J1900 up to 2 42 GHz Chipset Integrated System Memory DDR3 L 1333 SODIMM up to 8GB 204 Pin DIMM x 2 Network Ethernet Intel i210AT Gigabit Ethernet x 4 Bypass 2 NIM Slot Display Graphic...

Page 12: ...Ie slot Mini Card slot 1 IPMI Keyboard and Mouse Pin header Universal Serial Bus USB 2 0 x1 Box Header 2 0mm optional Miscellaneous RTC Internal RTC Watchdog Timer 1 255 steps by software programmable...

Page 13: ...C 40 C Storage Temp 4 F 140 F 20 C 60 C Operating Humidity 10 80 Storage Humidity 10 80 40 C non condensing Vibration 0 5 Grms 5 500Hz operation 3 5 H D D 1 5 Grms 5 500Hz no operation Shock 10G peak...

Page 14: ...nt Panel Power LED x 1 Status LED x 1 HDD Active LED x 1 LAN ports Link Active LED x 4 Bypass LED Default 2 LEDs USB 2 0 Ports x 2 RJ 45 Console x 1 Parallel LCM display and 4 keypad x 1 Software Prog...

Page 15: ...Network Appliance F W S 7 2 5 0 Chapter 1 General Information 1 8 1 4 General System Information...

Page 16: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 1 Quick Installation Guide Chapter 2...

Page 17: ...fic site 02 Access is by means of at least one of the following special tool lock and key or other means of security and is controlled by the authority responsible for the location Safety Precautions...

Page 18: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 3 2 2 Location of Connectors of Main Board...

Page 19: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 4...

Page 20: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 5 2 3 Mechanical Drawing of Main Board...

Page 21: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 6...

Page 22: ...tion CN16 CMOS Setting Selection CN17 RTC Test Setting Selection 2 5 List of Connectors The board has a number of connectors that allow you to configure your system to suit your application The table...

Page 23: ...1 Console Port Connector CN22 Giga LAN Port Connector CN23 Giga LAN Port Connector CN24 Giga LAN Port Connector CN25 Giga LAN Port Connector BT1 Battery COM1 COM Port Connector CPU_FAN1 4 Pin Fan Conn...

Page 24: ...them To close a jumper you connect the pins with the clip To open a jumper you remove the clip Sometimes a jumper will have three pins labeled 1 2 and 3 In this case you would connect either pins 1 a...

Page 25: ...n Guide 2 10 2 7 Auto Power Button JP1 1 2 3 JP1 Function 1 2 Disable Auto Power Button 2 3 Enable Auto Power Button 2 8 CF Power Selection CN13 1 2 3 CN13 Function 1 2 5V 2 3 3 3V 2 9 CMOS Setting Se...

Page 26: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 11 2 10 RTC Test Setting Selection CN17 1 2 3 CN17 Function 1 2 RTC Test 2 3 Normal...

Page 27: ...1 Pin Signal Signal Type Signal Level 1 3 3V PWR 3 3V 2 3 3V PWR 3 3V 3 GND GND 4 5V PWR 5V 5 GND GND 6 5V PWR 5V 7 GND GND 8 PWROK Input 5V 9 5VSB PWR 5V 10 12V PWR 12V 11 12V PWR 12V 12 3 3V PWR 3 3...

Page 28: ...PWR 5V 22 5V PWR 5V 23 5V PWR 5V 24 GND GND 2 12 Power Button CN2 Pin Signal Signal Type Signal Level 1 Power On Button Input 2 Power On Button Input 2 13 SIM Card Socket CN4 Pin Signal Signal Type Si...

Page 29: ...pactFlash Socket CN5 Pin Signal Signal Type Signal Level 1 GND GND 2 D3 Input Output 3 D4 Input Output 4 D5 Input Output 5 D6 Input Output 6 D7 Input Output 7 CS1 Output 8 A10 Output 9 ATA_SEL Output...

Page 30: ...ut 21 D0 Input Output 22 D1 Input Output 23 D2 Input Output 24 IOSC16 Output 25 CD2 Input 26 CD1 Input 27 D11 Input Output 28 D12 Input Output 29 D13 Input Output 30 D14 Input Output 31 D15 Input Outp...

Page 31: ...MARQ Input 44 DMACK Output 45 DASP Input Output 46 PDIAG Input Output 47 D8 Input Output 48 D9 Input Output 49 D10 Input Output 50 GND GND 2 15 LCM Connector CN6 Pin Signal Signal Type Signal Level 1...

Page 32: ...utput 13 DATA7 Input Output 5V Default 3 3V 14 DATA6 Input Output 15 LCD Output 16 5V PWR 5V 17 KEY PAD Up Input 3 3V 18 KEY PAD Right Input 3 3V 19 KEY PAD Left Input 3 3V 20 KEY PAD Down Input 3 3V...

Page 33: ...5 MS_DATA Input Output 6 MS_CLK Output 7 Key N A 8 N C Note Max rating for pin 4 is 0 55A at 5V 2 17 SATA Port Connector CN9 Pin Signal Signal Type Signal Level 1 GND GND 2 SATA_TXP2 DIFF 3 SATA_TXN2...

Page 34: ...el 1 12V PWR 12V 2 GND GND 3 GND GND 4 5V PWR 5V Note Max rating for pin 1 is 1A at 12V 2 19 USB2 0 Port 1 Pin Header CN11 Pin Signal Signal Type Signal Level 1 5V_USB3 PWR 5V 2 NC NC 3 USB3_N DIFF 4...

Page 35: ...Signal Type Signal Level 1 Red Output 2 5V_CRT PWR 5V 3 Green Output 4 GND GND 5 Blue Output 6 CRT_PLUG Input 7 N C 8 DDC_DATA Input Output 3 3V 9 GND GND 10 CRT_OHSYNCF Output 11 GND GND 12 CRT_OVSYN...

Page 36: ...Connector CN15 Pin Signal Signal Type Signal Level 1 GND GND 2 SATA_TXP1 DIFF 3 SATA_TXN1 DIFF 4 GND GND 5 SATA_RXN1 DIFF 6 SATA_RXP1 DIFF 7 GND GND 2 22 Mini PCI E Slot CN19 Pin Signal Signal Type Si...

Page 37: ...D 10 UIM_DATA Input Output 11 PCIE_CLK DIFF 12 UIM_CLK Input 13 PCIE_CLK DIFF 14 UIM_RESET Input 15 GND GND 16 UIM_VPP Input 17 N C 18 GND GND 19 N C 20 WLAN_EN Output 21 GND GND 22 PLT_RST Output 23...

Page 38: ..._DN DIFF 37 GND GND 38 USB_DP DIFF 39 3 3VDUAL PWR 3 3V 40 GND GND 41 3 3VDUAL PWR 3 3V 42 LED_WWAN Output 43 GND GND 44 LED_WLAN Output 45 Reserved N A 46 LED_WPAN Output 47 Reserved N A 48 1 5V PWR...

Page 39: ...nnector CN20 Pin Signal Signal Type Signal Level 1 5V_USB1 PWR 5V 2 USB1_N DIFF 3 USB1_P DIFF 4 GND GND 5 5V_USB2 PWR 5V 6 USB2_N DIFF 7 USB2_P DIFF 8 GND GND Note Max rating for pin 1 is 0 5A at 5V 2...

Page 40: ...DSR1 Output 9V 8 CTS1 Input 9 RI1 5V 12V Input PWR By Jumper Selection Note Max rating for pin 9 is 1A at 5V and 12V 2 25 Giga LAN Port Connector CN22 Pin Signal Signal Type Signal Level 1 LAN1_MDI0P...

Page 41: ...ort Connector CN23 Pin Signal Signal Type Signal Level 1 LAN2_MDI0P DIFF 2 LAN2_MDI0N DIFF 3 LAN2_MDI1P DIFF 4 LAN2_MDI2P DIFF 5 LAN2_MDI2N DIFF 6 LAN2_MDI1N DIFF 7 LAN2_MDI3P DIFF 8 LAN2_MDI3N DIFF 2...

Page 42: ...F 4 LAN3_MDI2P DIFF 5 LAN3_MDI2N DIFF 6 LAN3_MDI1N DIFF 7 LAN3_MDI3P DIFF 8 LAN3_MDI3N DIFF 2 28 Giga LAN Port Connector CN25 Pin Signal Signal Type Signal Level 1 LAN4_MDI0P DIFF 2 LAN4_MDI0N DIFF 3...

Page 43: ...pe Signal Level 1 DCD1 Input 2 RXD1 Input 3 TXD1 Output 9V 4 DTR1 Output 9V 5 GND GND 6 DSR1 Input 7 RTS1 Output 9V 8 CTS1 Input 9 RI1 5V 12V Input PWR By Jumper Selection 10 N C Note Max rating for p...

Page 44: ...7 NC 8 NC 9 NC 5V 12V PWR By Jumper Selection 10 N C Note Max rating for pin 9 is 1A at 5V 12V RS 485 Pin Signal Signal Type Signal Level 1 RS485_D DIFF 2 NC 3 RS485_D DIFF 4 NC 5 GND GND 6 NC 7 NC 8...

Page 45: ..._PWR PWR 12V 3 FAN_TAC Input 4 FAN_CTL Output 2 31 Front Panel Connector FP1 Pin Signal Signal Type Signal Level 1 External Speaker Output 2 Key Board Lock Output 3 NC Floting 4 GND POWER 5 External S...

Page 46: ...Power On Button Input 2 Reset Switch Input 3 Power On Button POWER 4 Reset Switch POWER 5 HDD LED POWER 6 Power LED POWER 7 HDD LED Output 8 Power LED Output Note Max rating for pin 1 2 3 4 7 8 are 0...

Page 47: ...etwork Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 32 2 34 Installing the 2 5 Hard Disk Drive Step 1 Remove the cover Step 2 Remove the HDD bracket Step 3 Put the screws into cushions...

Page 48: ...etwork Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 33 Step 4 Attach the assembled screws to HDD bracket Step 5 Place the HDD inside the bracket tighten the highlighted screws to secur...

Page 49: ...pliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 34 Step 6 Place the assembled HDD back to the chassis tighten the highlighted screws to secure Step 7 Connect the SATA cable and power cable...

Page 50: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 35 Repeat the steps above to install a second 2 5 HDD if any...

Page 51: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 36 2 35 Installing the 3 5 Hard Disk Drive Step 1 Remove the cover Step 2 Remove the bracket...

Page 52: ...pliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 37 Step 3 Secure the bracket to the underside of the hard disk Step 4 Place assembled HDD back to the chassis tighten the highlighted screws...

Page 53: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 38 Step 5 Connect the SATA cable and power cable to the HDD...

Page 54: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 39 China RoHS Requirements AAEON Boxer Industrial System Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006...

Page 55: ...Network Appliance F W S 7 2 5 0 Chapter 2 Quick Installation Guide 2 40...

Page 56: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 1 AMI BIOS Setup Chapter 3...

Page 57: ...he CMOS memory and BIOS NVRAM If system configuration is not found or system configuration data error is detected system will load optimized default and re boot with this default system configuration...

Page 58: ...M so that it retains the Setup information when the power is turned off Entering Setup Power on the computer and press Del immediately This will allow you to enter Setup Main Set the date use tab to s...

Page 59: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 4 Setup Menu Setup submenu Main...

Page 60: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 5 Setup submenu Advanced...

Page 61: ...e F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 6 CPU Configuration Options summary Intel Virtualization Technology Disabled Optimal Default Failsafe Default Enabled EIST Disabled Optimal Default Failsafe...

Page 62: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 7 IDE Configuration IDE Options summary SATA Mode IDE Mode Optimal Default Failsafe Default AHCI Mode...

Page 63: ...ation Options summary Legacy USB Support Enabled Optimal Default Failsafe Default Disabled Auto Enables BIOS Support for Legacy USB Support When enabled USB can be functional in legacy environment lik...

Page 64: ...isabled Optimal Default Failsafe Default Enabled CPU_FAN Smart Control Enable FAN Control Mode Manual Mode Optimal Default Failsafe Default Automatic Mode Manual Mode PWM Duty 0 255 Automatic Mode Spi...

Page 65: ...Default Failsafe Default Enabled SYS_FAN Smart Control Enable FAN Control Mode Manual Mode Optimal Default Failsafe Default Automatic Mode Manual Mode PWM Duty 0 255 Automatic Mode Spin PWM 0 255 Off...

Page 66: ...ect power supply mode AC Power Loss Last State Optimal Default Failsafe Default Always On Always Off Select power state when power is re applied after a power failure RTC wake system from S5 Disabled...

Page 67: ...s LED Configuration LED OFF Optimal Default Failsafe Default RED LED ON RED LED BLINK RED LED FAST BLINK GREEN LED ON GREEN LED BLINK GREEN LED FAST BLINK LAN Bypass Kit 1 Configuration Mode for power...

Page 68: ...Setup 3 13 LAN Bypass Kit 2 Configuration Mode for power on PassTru Optimal Default Failsafe Default Bypass Mode for power off PassTru Optimal Default Failsafe Default Bypass WDT Configuration Force B...

Page 69: ...BIOS Setup 3 14 Serial Port Console Redirection Options summary COM0 Console Redirection Enable Optimal Default Failsafe Default Disable Windows Emergency Management Services EMS Console Redirection E...

Page 70: ...p 3 15 COM0 Console Redirection Settings Options summary Terminal Type VT100 Optimal Default Failsafe Default VT100 VT UTF8 ANSI Bits per second 9600 Optimal Default Failsafe Default 19200 38400 57600...

Page 71: ...UTF8 Combo Key Support Disable Optimal Default Failsafe Default Enable Recorder Mode Disable Optimal Default Failsafe Default Enable Resolution 100x31 Disable Optimal Default Failsafe Default Enable...

Page 72: ...Redirection Settings Options summary Terminal Type VT100 Optimal Default Failsafe Default VT100 VT UTF8 ANSI Bits per second 9600 Optimal Default Failsafe Default 19200 57600 115200 Flow Control None...

Page 73: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 18 SIO Configuration...

Page 74: ...ial Port 1 Configuration Options summary Use This Device Disabled Enabled Optimal Default Failsafe Default En Disable Serial Port COM Possible Use Automatic Settings Optimal Default Failsafe Default I...

Page 75: ...ial Port 2 Configuration Options summary Use This Device Disabled Enabled Optimal Default Failsafe Default En Disable Serial Port COM Possible Use Automatic Settings Optimal Default Failsafe Default I...

Page 76: ...d Optimal Default Failsafe Default En Disable Serial Port COM Possible Use Automatic Settings Optimal Default Failsafe Default IO 378 IRQ 5 IO 378 IRQ 5 6 7 9 10 11 12 IO 278 IRQ 5 6 7 9 10 11 12 IO 3...

Page 77: ...2 PS2 Keyboard Configuration Options summary Use This Device Disabled Enabled Optimal Default Failsafe Default En Disable Serial Port COM Possible Use Automatic Settings Optimal Default Failsafe Defau...

Page 78: ...BIOS Setup 3 23 PS2 Mouse Options summary Use This Device Disabled Enabled Optimal Default Failsafe Default En Disable Serial Port COM Possible Use Automatic Settings Optimal Default Failsafe Default...

Page 79: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 24 Setup submenu Chipset...

Page 80: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 25 North Bridge...

Page 81: ...Setup 3 26 Display Control Configuration Options summary DVMT Pre Allocated 64M Optimal Default Failsafe Default 96M 128M 160M 192M 224M 256M 288M 320M 352M 384M 416M 448M 480M 512M DVMT Total Gfx Me...

Page 82: ...ighlight these items and press Enter a dialog box appears which lets you enter a password You can enter no more than six letters or numbers Press Enter after you have typed in the password A second di...

Page 83: ...28 Setup submenu Boot Options summary Quiet Boot Disabled Enabled Default En Disable showing boot logo Option ROM Messages Force BIOS Default Keep Current Set display mode for Option ROM Launch PXE Op...

Page 84: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 29 BBS Priorities...

Page 85: ...Network Appliance F W S 7 2 5 0 Chapter 3 AMI BIOS Setup 3 30 Setup submenu Exit...

Page 86: ...Network Appliance F W S 7 2 5 0 Chapter 4 Driver Installation 4 1 Driver Installation Chapter 4...

Page 87: ...aaeon com en p rackmount network appliance fws 7250 Once you have downloaded the files follow the steps below to install the drivers Follow the sequence below to install the drivers Step 1 Install Ch...

Page 88: ...et exe file 2 Follow the instructions 3 Drivers will be installed automatically Step 2 Install VGA Driver 1 Open on the Step 2 Graphics folder and select your OS 2 Open the Setup exe located in the fo...

Page 89: ...CI folder and open the Setup exe file 2 Follow the instructions 3 Drivers will be installed automatically Step 5 Install Intel Sideband Fabric Device Driver 1 Open the Step 5 Intel Sideband Fabric Dev...

Page 90: ...Network Appliance F W S 7 2 5 0 Appendix A Programming the Watchdog Timer A 1 Programming the Watchdog Timer Appendix A...

Page 91: ...MB PnP Mode Data Register 0x2F or 0x4F Table 2 Watchdog relative register table LDN Register BitNum Value Note Timer Counter 0x07 Note3 0x73 Note4 Note24 Time of watchdog timer 0 255 This register is...

Page 92: ...rVal This parameter is represented from Note24 define byte UnitLDN This parameter is represented from Note5 define byte UnitReg This parameter is represented from Note6 define byte UnitBit This parame...

Page 93: ...mming the Watchdog Timer A 4 VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This proc...

Page 94: ...DN EnableReg EnableBit 0 Clear Watchdog Timeout Status WDTClearTimeoutStatus WDT relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOB...

Page 95: ...Index 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0x55 Break Case 0x4E IOWriteByte SIOIndex 0x87 IOWriteByte SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0xAA Break VOID SIOExi...

Page 96: ...Value SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOBy...

Reviews: