Safety Instructions:

 

 

This manual contains important instructions for the GV-Boost GVB-8-Pb-**V and GVB-8-Li-**.*V 

solar charge controllers that shall be followed during installation and maintenance. Various models 

of the GVB are available to charge different battery types as follows:

 

 

GVB

8

Pb

12V:

 

12V   Lead-Acid/AGM/Gel/Sealed/Flooded

 

 

GVB

8

Pb

24V:

 

24V    Lead-Acid/AGM/Gel/Sealed/Flooded

 

 

GVB

8

Pb

36V:

 

36V    Lead-Acid/AGM/Gel/Sealed/Flooded

 

 

GVB

8

Pb

48V:

 

48V   Lead-Acid/AGM/Gel/Sealed/Flooded

 

 

GVB

8

Li

**.*V:

 

Custom Lithium Variation

 

Consult your battery charging specifications to ensure that the GVB is compatible with your chosen 
batteries.

 

 

 

Carefully follow these instructions.

 

 

 

CAUTION for the GVB-8-Pb-**V

(lead-acid Versions only):

 

Internal temperature Compensation. Risk of Fire, use Within 0.3 m (1 ft) of Batteries.  

lead-

acid batteries can create  explosive gases.  short circuits can draw thousands of amps from a 

battery.  Carefully read and follow all instructions

 

supplied with the battery.

 

 

 

DO NOT SHORT CIRCUIT 

the solar array when plugged into the controller. 

do not measure short 

Circuit Current 

of the array  while connected to the controller.  this will destroy the controller, and 

such damage will not be covered under warranty.

 

 

 

LITHIUM WARNING: 

take caution when working with lithium systems.  The  controllers use the 

CC/CV charging profile 

indicated on the controller.  Check the specifications of the battery pack to 

ensure that the CV voltage is correct. Further check  that  the power supplied by the solar array 

and    controller is within the battery specified design limits.

 

 

LITHIUM BMS WARNING:

   recommend using a lithium battery with a Battery management system 

capable of  disconnecting the solar charge controller in the event that any cell in the pack is 

outside of its rated temperature, current, or  voltage range. Failure to do so may result in property 

damage, injury or death.  Highly recommends the use of a Bms with  cell balancing.  Cell 

balancing is mandatory for lithium-iron phosphate systems.

 

 

 

Use only 10-30 AWG copper conductors suitable for a minimum of 60 degrees C.  If operation at 

high power or at high ambient  temperatures is expected, wire with a higher temperature rating 

may be necessary.

 

 

Inspection

 

&

 

Maintenance

 

 

Inspect the controller at least once per year to ensure proper performance.

 

• 

Check for animal or insect damage.

 

• 

Inspect for corrosion / water damage.

 

• 

Inspect the security of all connections.

 