49
Value
97,0
97,0
0,0
0,0
17
89,2
MODEL
Hot air generators B1 (yes - no)
C2 hot air generators (yes - no)
C4 hot air generators (yes - no)
Type of fuel (gaseous / liquid / electricity)
(*) not required for electric hot air generators
(**) from 26 September 2018
MEC MIX F 35 - 70 CENTRIFUGES
NO
NO
SI
Gaseous
Element
CAPACITY
Nominal heating capacity
Minimum capacity
ELECTRICITY CONSUMPTION*
At the nominal heating capacity
At the minimum capacity
In stand-by mode
Contact
Element
USEFUL EFFICIENCY
Useful efficiency for nominal heating capacity *
Useful efficiency at minimum capacity *
HIGH ELEMENTS
Loss of casing factor
Burner consumption
Emissions of nitrogen oxides (*) (**)
Emission efficiency
Seasonal energy efficiency of space heating
A2B ACCORRONI E.G. Via d’Ancona, 37 - 60020 Osimo (AN)
Symbol
P ated, h
P min
el max
el min
el sb
Symbol
µ mon
µ pl
F env
P ing
Nox
µs flow
µs,h
Value
35,06
35,06
0,779
0,779
0,009
U.M.
kW
kW
kW
kW
kW
U.M.
%
%
%
%
mg/kWh
input power(GCV)
%
%
11.6 TABLE OF MAIN REQUIREMENTS MEC MIX F 35 - 70 CENTRIFUGES
11.5 TABLE REQUIREMENTS MAIN MEC MIX F 35 - 70 AXIALS
Value
96,4
96,4
0,0
0,0
31
91,3
MODEL
Hot air generators B1 (yes - no)
C2 hot air generators (yes - no)
C4 hot air generators (yes - no)
Type of fuel (gaseous / liquid / electricity)
(*) not required for electric hot air generators
(**) from 26 September 2018
MEC MIX F 35 - 70 AXIALS
NO
NO
SI
Gaseous
Element
CAPACITY
Nominal heating capacity
Minimum capacity
ELECTRICITY CONSUMPTION*
At the nominal heating capacity
At the minimum capacity
In stand-by mode
Contact
Element
USEFUL EFFICIENCY
Useful efficiency for nominal heating capacity *
Useful efficiency at minimum capacity *
HIGH ELEMENTS
Loss of casing factor
Burner consumption
Emissions of nitrogen oxides (*) (**)
Emission efficiency
Seasonal energy efficiency of space heating
A2B ACCORRONI E.G. Via d’Ancona, 37 - 60020 Osimo (AN)
Symbol
P ated, h
P min
el max
el min
el sb
Symbol
µ mon
µ pl
F env
P ing
Nox
µs flow
µs,h
Value
35,12
35,12
0,409
0,409
0,009
U.M.
kW
kW
kW
kW
kW
U.M.
%
%
%
%
mg/kWh
input power(GCV)
%
%