Set P7.16 to 1 if the motor speed is required to decrease with the
increase of the reference.
P7.17~P7.28 Reserved
Reserved
P7.29 PID feedback break line detection
Range: 0.0
~
80.0%
【
0.00%
】
P7.30 PID feedback break line detection time
Range: 0.0
~
999.9s
【
0.00s
】
If set P7.29 to 0.0%, no feedback break line detection
Feedback break line detection threshold is a percentage of the full
feedback.
If PID feedback signal is less than P7.29 and last more than setting time
of P7.30, feedback break line alarm will appears.
Note:
Please set P7.29 reasonabely, if not, will cause unnecessary downtime.
7.9 MS parameters ( P8 )
P8.00 MS freq. 1
Range: lower limit
~
upper limit
【
5.00Hz
】
P8.01 MS freq. 2
Range: lower limit
~
upper limit
【
10.00Hz
】
P8.02 MS freq. 3
Range: lower limit
~
upper limit
【
20.00Hz
】
P8.03 MS freq. 4
Range: lower limit
~
upper limit
【
30.00Hz
】
P8.04 MS freq. 5
Range: lower limit
~
upper limit
【
40.00Hz
】
P8.05 MS freq. 6
Range: lower limit
~
upper limit
【
45.00Hz
】
P8.06 MS freq. 7
Range: lower limit
~
upper limit
【
50.00Hz
】
P8.07~P8.14 MS freq. 8~ 15
Range: lower limit
~
upper limit
【
50.00Hz
】
P8.15~P8.20 Reserved
Reserved
7.10 Enhanced function ( P9 )
Table 7-12 Carrier Freq. and Performance
Carrier wave Freq.
Decreasing
Increaseing
Motor noise
↑
↓
P7.31~P7.33 Reserved
Reserved
P9.00~P9.01 Reserved
Reserved
P9.02 Carrier wave frequency
Range: 0.7
~
15.0kHz
【
6.0kHz
】