![A.T.I.B. HFK Series Use And Maintenance Manual Download Page 13](http://html.mh-extra.com/html/a-t-i-b/hfk-series/hfk-series_use-and-maintenance-manual_447904013.webp)
Addendum Release
5.10 F
1 / 1
26 mar 2014 (dd/mm/yy)
ATIB ELETTRONICA S.R.L
V
IA
I
NDUSTRIALE
, 29 Z.I. B
ARBARIGA
(BS) Tel. +39 030 99 71 051 E-mail: [email protected]
Main Parameter
Stop
Stop
Charger is idle. Battery can be disconnected avoiding electric arcs
E 0
F 00
Stage 0.0
Starting charge.
E 0
F 10
Stage 1.0
Bulk stage (before gassing point).
E 0
F 20
Stage 2.0
Absorption stage - Constant voltage (gassing point threshold)
E 0
F 30
Stage 3.0
Final stage - Low constant current.
E 0
end4
End5
Stage 4
Stage 5
Floating stage. Main charge is completed
Stage 4 – fixed floating ; Stage 5 – pulse floating;
E 0
end
End
Charge is over. Cycle completed. Battery can be disconnected.
E 0
endb
End
Charge is over. Cycle short. Battery was likely full charged or sulphated.
E 0
wait
Wait
Charge is not started yet. A delayed start has been set.
E 19
Error Codes
bat
Battery
Battery not connected. It simply means it should be connected. If not
means battery voltage too low or output fuse blown.
E 1
bat1
Battery 1
Battery undervoltage. Battery is under of the setting range.
E 3
bat9
Battery 9
Battery overvoltage.
E 12
t' I
t° IGBT
IGBT overheating. Charger is waiting for cooling or probe failure
E 4
t'D1
t° Diode
Diode 1 overheating. Charger is waiting for cooling or probe failure
E 5
t'd2
t° Diode
Diode 2 overheating. Charger is waiting for cooling or probe failure
E 6
cur
Current
Current below minimal threshold.
E 10
main
Main
One or more of AC main phases is missing or one or more input fuses
into wall socket or into the charger are blown.
E 11
time
Time F1
Stage 1 maximum time. Gassing point is not reached within this time.
E 7
tout
Tmax
Global charging time. Charging cycle has exceeded this safety time.
E 7
ON-OFF button
Pressing P4 button during the charge the display shows
off
Pressing P4 again the Charger switches off. The display shows
Stop
After switching off, wait until the display shows
bat
before starting a new
charge.