FSE Series Electric Actuator
Installation & Maintenance Manual
4
November 18, 2022
www.atcontrols.com
Engineering\documents\products\IOM\Iom08026.docx
Inspection, Storage, Transport
Receiving/Inspection
Carefully inspect the package for any damage resulting from shipping and report all damages to freight
carrier and seller.
After unpacking, please keep cartons and packing materials in case of product return or replacement. Verify
the items listed in packing slip or in bill of landing are the same as what were ordered, If there is any
discrepancy, please contact the seller.
Verify the technical data on nameplate and labels is in accordance with what was ordered.
Storage
The actuator should be stored in a dry area with relative humidity less than 90% (68±9°F / 20±5°C) and at
temperatures between -4°F to 104°F (-20°C to 40°C).
The product shall be stored with suitable protection from weather, extreme vibration and corrosive
substances that can damage the actuator.
Conduit plugs should not be removed until the actuator is ready to be cabled. Use suitable connections to
ensure enclosure rating is maintained when installing.
Transport
Attach ropes or hooks for the purpose of lifting by hoist only to housing and not to handwheel.
Packaged actuators shall avoid violent impact and strong vibrations and be protected from precipitation.
Lubrication
The gear train has been sufficiently lubricated at the factory and requires no additional lubrication.