A-Plus Water DuraLine Manual Download Page 6

 

 
 
 
 
 
Screen Four

SET THRESHOLD TOTAL  2

 (factory set at 80)   

 

 

    
Set this option for the total amount of gallons required to deliver a  
service call alert to the customer 
 

 

Set threshold gallons (x1000) 

Recommended setting for 9x48 system is 80; 10x54 system is120 

 

Yellow light blinks at 80% threshold 

 

Red light blinks at 90% threshold 

 

Alarm beeps at 100% threshold 

 

Opt2 connection is powered with 12 VAC at 100% threshold  
(30 milliamps (mA) max.) 

 

Press the Flow button to advance to next screen 
 

Screen Five

SET GAL/MIN

 (no factory setting)      

 

    

                   

This function is primarily for an external device, i.e. a secondary pump,  
chemical feed or auxiliary signal, etc 

 

Set GPM for the 20 mA output flow rate 

 

Zero flow is a fixed 4 mA output   

 

Verify polarity 4-20 mA output at J2 connection 

 

4-20 mA proportional flow rate output 

 

Press the Flow button to advance to next screen 
 

Screen Six

SET GAL 1 

(factory set at 20) 

This setting fixes the number of gallons before auto pump starts 

 

Set the gallon batch to energize Opt1 connection 

 

Set at 10 gallons 
   For Air Pump factory setting is 20 gal 
   Feed Pump setting is 1 gal. for 10 GPM peak flow; 2 gal. for 20 GPM  
   peak flow; 3 gal. for 30 GPM peak flow;  4 gal. for 40 GPM peak flow 

 

A setting of zero energizes Opt1 like a flow switch, sensitive at .5 GPM 

 

Press the Flow button to advance to next screen  

 

Screen Seven

SET MIN 1

    

 

 

 

 

 

 

  

This setting factors the run time duration of the auto air pump or  
feed pump after water usage has discontinued (.1 would be 6 seconds.)

 

 

Set delay off in minutes for Air Pump - Opt1 connection 

 

Set between 0.1 and 90 minutes.  
   Air Pump setting is .33min 
   Feed pump setting is 0.10 min. 

 

Opt1 is 12 VAC (30 mA max.) 

 

Press the Flow button to advance to next screen 
 

*Please contact your water professional to confirm the proper settings for your application. The above values are recommendations 
only. 
 
 

  

Summary of Contents for DuraLine

Page 1: ......

Page 2: ...Description 2 Application 3 Installation 3 Instructions 3 Programming 4 5 Flow Meter Control Board 6 Data Recording 7 Contact Information 8 ...

Page 3: ... flow rate output Green LED light indicates power is on 235 pulses per gallon using meter Adjustable threshold alarm system 1 40 GPM 5 80 threshold flashing Yellow light Multiple quick connect fittings 90 threshold flashing Red light high flow turbine meter 100 threshold Audible alarm Noryl body with ABS bezel Flow switch 12 V AC output 100 threshold 12 V AC output ...

Page 4: ...last meter reset gal Peak Flow Displays peak flow rate since last meter reset gal min Lights Green Power Light System is plugged in and fully functioning Yellow Warning Light Blinks when system is at 80 of threshold gallons Red Expired Light Blinks when system is at 90 of threshold gallons Alarm Beep 3 beeps every 15 seconds at 100 threshold gallons Push any button to silence the beep for two days...

Page 5: ...ng For initial set up select NO Press the Flow button to advance to next screen Screen Two SET PULSES factory set at 235 for Hall Effect meter Set pulses per gallon PPG for Hall Effect meter For initial set up confirm pulse is set at 235 Press the Flow button to advance to next screen Screen Three SET THRESHOLD TOTAL 2 YES NO YES to use threshold function NO to turn off threshold function this act...

Page 6: ... button to advance to next screen Screen Six SET GAL 1 factory set at 20 This setting fixes the number of gallons before auto pump starts Set the gallon batch to energize Opt1 connection Set at 10 gallons For Air Pump factory setting is 20 gal Feed Pump setting is 1 gal for 10 GPM peak flow 2 gal for 20 GPM peak flow 3 gal for 30 GPM peak flow 4 gal for 40 GPM peak flow A setting of zero energizes...

Page 7: ...UTPUT CONNECTION POWER CONNECTION FLOW METER INPUT CONNECTION TERMINAL COLORS BLACK WHITE BLUE AS SHOWN OPTO OUTPUT CONNECTION OUTPUT2 COMMON OUTPUT 1 12 VAC 30MA RED ALARM LED YELLOW WARNING LED GREEN POWER ON LED WARNING BUZZER ...

Page 8: ...Job Description Date Time Value Before Value After ...

Page 9: ...Thank you again for choosing this Electronic Meter Assembly for your water treatment system Please contact your service professional with questions Place contact information here ...

Reviews: