A-Plus Water DuraLine Manual Download Page 4

 

 
 
 
Application 

The meter control unit reads a standard Hall Effect water meter output to display flow. The meter control unit can also be 
used with industry standard auxiliary air pumps, chemical feeds, or other electro-mechanical products that require 
precision measures based on water usage. 

 

 
 
Installation 

The meter control is available as a companion to the complete line of water solution equipment. Mounting for the In/Out 
Head and Connection Manifold are standard with the industry.  

 

 
 
Instructions 

The display on the meter control unit shows the following values when the corresponding button is pressed (left to right 
across the display) 

NOTE:

 WRITE DOWN ALL VALUES BEFORE AND AFTER SETUP. (Record data on Page 7 of this manual) 

 

Flow: Displays current flow rate, gal/min. 

 

Total Flow: Displays total gallons treated since last meter reset, gal. 

 

Peak Flow: Displays peak flow rate since last meter reset, gal/min. 

 
Lights: 

 

Green Power Light: System is plugged in and fully functioning. 

 

Yellow Warning Light: Blinks when system is at 80% of threshold gallons. 

 

Red Expired Light: Blinks when system is at 90% of threshold gallons. 

 
Alarm Beep: 

 

3 beeps every 15 seconds at 100% threshold gallons. 

 

Push any button to silence the beep for two days. 

 

Please refer to the Clear Memory section of this manual to reset meter for new monitoring cycle. 

 

Output 2 connection is powered with 12 V AC at 100% threshold gallons. 

 
Clear Memory (Stops the Beeping): 

NOTE:

 WRITE DOWN ALL VALUES AND DATES BEFORE CLEARING MEMORY FOR FUTURE 

REFERENCE. (Record data on Page 7 of this manual)  

 

Clearing the memory will stop the 100% threshold beep and zero out the Total Flow and Peak Flow values.  

 

Press and hold all 3 buttons simultaneously. Screen will display “CLR MEMORY NO”. 

 

Press the “Total Flow” or “Peak Flow” button. Screen will display “CLR MEMORY YES”. 

 

Press the “Flow” button to clear memory. 

 

 
 
 
 
 

Summary of Contents for DuraLine

Page 1: ......

Page 2: ...Description 2 Application 3 Installation 3 Instructions 3 Programming 4 5 Flow Meter Control Board 6 Data Recording 7 Contact Information 8 ...

Page 3: ... flow rate output Green LED light indicates power is on 235 pulses per gallon using meter Adjustable threshold alarm system 1 40 GPM 5 80 threshold flashing Yellow light Multiple quick connect fittings 90 threshold flashing Red light high flow turbine meter 100 threshold Audible alarm Noryl body with ABS bezel Flow switch 12 V AC output 100 threshold 12 V AC output ...

Page 4: ...last meter reset gal Peak Flow Displays peak flow rate since last meter reset gal min Lights Green Power Light System is plugged in and fully functioning Yellow Warning Light Blinks when system is at 80 of threshold gallons Red Expired Light Blinks when system is at 90 of threshold gallons Alarm Beep 3 beeps every 15 seconds at 100 threshold gallons Push any button to silence the beep for two days...

Page 5: ...ng For initial set up select NO Press the Flow button to advance to next screen Screen Two SET PULSES factory set at 235 for Hall Effect meter Set pulses per gallon PPG for Hall Effect meter For initial set up confirm pulse is set at 235 Press the Flow button to advance to next screen Screen Three SET THRESHOLD TOTAL 2 YES NO YES to use threshold function NO to turn off threshold function this act...

Page 6: ... button to advance to next screen Screen Six SET GAL 1 factory set at 20 This setting fixes the number of gallons before auto pump starts Set the gallon batch to energize Opt1 connection Set at 10 gallons For Air Pump factory setting is 20 gal Feed Pump setting is 1 gal for 10 GPM peak flow 2 gal for 20 GPM peak flow 3 gal for 30 GPM peak flow 4 gal for 40 GPM peak flow A setting of zero energizes...

Page 7: ...UTPUT CONNECTION POWER CONNECTION FLOW METER INPUT CONNECTION TERMINAL COLORS BLACK WHITE BLUE AS SHOWN OPTO OUTPUT CONNECTION OUTPUT2 COMMON OUTPUT 1 12 VAC 30MA RED ALARM LED YELLOW WARNING LED GREEN POWER ON LED WARNING BUZZER ...

Page 8: ...Job Description Date Time Value Before Value After ...

Page 9: ...Thank you again for choosing this Electronic Meter Assembly for your water treatment system Please contact your service professional with questions Place contact information here ...

Reviews: