16
A1-M-XL
6. MAINTENANCE
6.1 STATE OF MAINTENANCE
The maintenance operations must be performed with the machine in the conditions of “Isolation for maintenance”.
6.3 SPECIAL CAUTIONS
During the maintenance or repair operations is suggested to proceed as follows:
• Before starting any operation place a sign “machine under maintenance” in a well visible position.
• Do not use solvents or flammable materials.
• Do not disperse into the environment lubricating liquids that have ozone harmful propellents.
• Do not step on the machine parts, because they have not been projected to sustain the weight of persons.
• Put on a pair of safety glasses.
• Once all the operations are finished replace any parts you removed or opened.
6.4 CLEANING
The machine structure is simple and robust therefore the mechanical parts do not require any special maintenance.
It is advisable to follow the rules listed below:
• Regularly remove glue or other residues from the Wedge head and from the upper part of the driver blade;
• Always keep the wedge magazine clean and without residues.
• Remove any residues from the Wedges guide “L” shaped support.
Do not use water to clean the machine, otherwise metallic parts may rust.
6.5 ROUTINE MAINTENANCE OPERATION
Frequency
Ispection
Action
Every 1.000.000 wedges shot
wedges driver blade
Replace
Every 300 working hours
Movable parts lubrication
Lubricate
Every 5.000.000 wedges shot
wedges claw-heads
Replace
Every 5.000.000 wedges shot
“L” shaped supports (wedges guide)
Replace