32
Instruction manual TWI 35-130 G/TWI 45-190 G
3.11.2 Adjust the CO
2
-value
For preparation remove the cover plate (2) from the electricity part by loosening
the two screws (1).
1.
Remove the cap (3) from the CO
2
setting screw (4).
2.
Insert a long screwdriver into the setting hole (5) along the air supply pipe.
3.
Correct the CO2-value dependent on the deviation by turning the CO
2
setting screw (4).
- CO
2
setting screw clockwise: CO
2
-value decreases
- CO
2
setting screw counterclockwise: CO
2
-value increases
4.
Put back the cap (3) on the CO2 setting screw (4).
5.
Remount the cover plate (1).
Remark
Before starting up, take the time for completing the delivered warranty
card. In this way you enable us to guarantee the quality of our systems and to
optimise our warranty procedure.
Return this card as soon as possible. Your customer will then receive a
warranty certificate with our terms of warranty.
3
Installation
Summary of Contents for TWI 35-130
Page 4: ...4 Instruction manual TWI 35 130 G TWI 45 190 G...
Page 23: ...Instruction manual TWI 35 130 G TWI 45 190 G 23 Device types IMD 0531 R0...
Page 34: ...34 Instruction manual TWI 35 130 G TWI 45 190 G 4 Conversion to another gas category...
Page 42: ...42 Instruction manual TWI 35 130 G TWI 45 190 G 8 Shut down...
Page 52: ...52 Instruction manual TWI 35 130 G TWI 45 190 G Maintenance 10...
Page 58: ...58 Instruction manual TWI 35 130 G TWI 45 190 G Annex 12...
Page 61: ...Instruction manual TWI 35 130 G TWI 45 190 G 61...
Page 62: ...62 Instruction manual TWI 35 130 G TWI 45 190 G...
Page 63: ...Instruction manual TWI 35 130 G TWI 45 190 G 63...
Page 64: ...64 Instruction manual TWI 35 130 G TWI 45 190 G 0311935 R0...