ST 300
Installation, Service and User Manual
29
2
Installation
2.1 Installation diagram
This figure shows the installation diagram. This diagram is referred to in the sections
describing the actual connection procedure.
Installation Diagram
Legend
1. pressure relief valve
(mandatory if mains water
pressure is too high)
3. T&P-valve
4. stop valve (recommended)
5. non-return valve
(mandatory)
6. circulation pump (optional)
9. drain valve
11. service stop valve
12. temperature gauge
(optional)
14. draw-off points
15. expansion valve
(mandatory)
16. expansion vessel
(mandatory)
A. cold water supply
B. hot water supply
C. circulation pipe
IMD-1285 R0
2.2 Water connections
2.2.1
Warning
The installation should be carried out by a competent person, in compliance with
general and locally applicable regulations.
Cold water side
See (A) in the installation diagram (2.1 "Installation diagram").
1. Fit an approved stop valve (4) on the cold water side as required by the
applicable regulations.
2. The maximum working pressure of the storage tank is 10 bar. Because the
pressure in the water pipe at times can exceed 10 bar, you must fit an approved
pressure-reducing valve (1).
3. Fit a non-return valve (5) and an expansion vessel (16).
4. Fit an expansion valve (15) and connect the overflow side to an open waste water
pipe.
Summary of Contents for ST-300
Page 4: ...ST 300 4...
Page 6: ...ST 300 Installatie Service en Gebruikershandleiding 6...
Page 8: ...ST 300 Installatie Service en Gebruikershandleiding 8...
Page 12: ...ST 300 Installatie Service en Gebruikershandleiding 12...
Page 22: ...ST 300 Installation Service and User Manual 22...
Page 24: ...ST 300 Installation Service and User Manual 24...
Page 28: ...ST 300 Installation Service and User Manual 28...
Page 38: ...ST 300 Notice d installation Mode d emploi Notice d entretien 38...
Page 40: ...ST 300 Notice d installation Mode d emploi Notice d entretien 40...
Page 44: ...ST 300 Notice d installation Mode d emploi Notice d entretien 44...