Voorraadvat
Storage tank
Ballons de stockage

ST - 300

ST

Installatie-, Gebruikers- en
Servicehandleiding

Notice d’installation, Mode d’emploi,
Notice d’entretien

Installation, User and Service
Manual

2617 - W

ijzigingen voorbehouden / Changes Reser

ved / Réser

ve de modifications.

Summary of Contents for ST-300

Page 1: ...age tank Ballons de stockage ST 300 ST Installatie Gebruikers en Servicehandleiding Notice d installation Mode d emploi Notice d entretien Installation User and Service Manual 2617 Wijzigingen voorbeh...

Page 2: ...ampshire GU14 0NR www aosmith co uk A O Smith France 14 all e Charles Path 18000 Bourges www aosmith fr 008008 AOSMITH 2676484 A O Smith Hoofdkantoor Europa De Run 5305 5503 LW Veldhoven www aosmith n...

Page 3: ...L 2 UK 3 FR NL Deze handleiding bestaat uit 3 talen Handleiding ST 300 5 Manual ST 300 21 Notice ST 300 37 UK This manual consists of 3 languages Handleiding ST 300 5 Manual ST 300 21 Notice ST 300 37...

Page 4: ...ST 300 4...

Page 5: ...roducts Company is niet aansprakelijk voor claims van derden veroorzaakt door ondeskundig gebruik anders dan vermeld in deze handleiding en overeenkomstig de Algemene Voorwaarden gedeponeerd bij de Ka...

Page 6: ...ST 300 Installatie Service en Gebruikershandleiding 6...

Page 7: ...stelling 9 Werkruimte 9 Verpakking 9 Afvoeren 9 Algemene gegevens 10 Afmetingen 10 Installatie 13 Aansluitschema 13 Wateraansluitingen 13 Vullen en Aftappen 15 Vullen 15 Aftappen 16 Onderhoud 17 Onder...

Page 8: ...ST 300 Installatie Service en Gebruikershandleiding 8...

Page 9: ...ordt afgeweken dan kan de bescherming van de tank niet worden gegarandeerd 4 Garantie In verband met de bereikbaarheid van het toestel wordt aanbevolen de volgende afstanden in acht te nemen bij de an...

Page 10: ...ngen Afmetingen Eenheid ST 300 A Totale hoogte mm 1650 D Diameter mm 750 M Hoogte koudwatertoevoer mm 110 N Hoogte warmwateruitlaat mm 1460 P Hoogte reinigingsopening mm 280 R Hoogte aansluiting mm 10...

Page 11: ...ST 300 Installatie Service en Gebruikershandleiding 11 Vooraanzicht doorsnede toestel IMD 1281 R0...

Page 12: ...ST 300 Installatie Service en Gebruikershandleiding 12...

Page 13: ...rmwaterafvoer C circulatieleiding IMD 1284 R0 2 2 Wateraansluitingen 2 2 1 Waarschuwing De installatie dient te geschieden door een erkend installateur en overeenkomstig de algemeen en plaatselijke ge...

Page 14: ...behoeve van servicedoeleinden 4 Is een circulatieleiding nodig ga dan verder met het monteren van de circulatieleiding 2 2 3 Circulatieleiding Zo niet monteer dan de bij de aftapkraan geleverde afdich...

Page 15: ...2 Sluit aftapkraan 3 Open het dichtstbijzijnde tappunt 4 Open de toevoerkraan van de inlaatcombinatie 2 zodat koud water het toestel instroomt 5 Vul het toestel volledig Als uit het dichtstbijzijnde t...

Page 16: ...en Gebruikershandleiding 16 3 2 Aftappen 1 Sluit de afsluiter in de warmwaterleiding 2 Sluit de toevoerkraan van de inlaatcombinatie 2 3 Open de aftapkraan 4 Belucht het toestel of installatie zodat...

Page 17: ...Controleer de afvoerleidingen van de overstortventielen en verwijder aanwezige kalkresten 3 Tap het toestel af Het waterzijdig onderhoud bestaat uit het ontkalken en reinigen van de tank en het contro...

Page 18: ...nen de bouten aangedraaid te worden met een moment van maximaal 50 Nm Gebruik hiervoor geschikt gereedschap Controle anodes Anodes zorgen voor de bescherming van de tank door zich zelf op te offeren W...

Page 19: ...tievoorschriften van A O Smith geldend voor het specifieke model als de plaatselijk geldende installatie en bouwverordeningen voorschriften en regelingen van overheidswege b Het voorraadvat blijft ge...

Page 20: ...even garantie gaat niet verder dan kosteloze levering af magazijn van de te vervangen delen of onderdelen respectievelijk voorraadvat vervoers arbeids installatie en andere met de vervanging verband h...

Page 21: ...rised use use other than that stated in this manual and use other than in accordance with the General Conditions registered at the Chamber of Commerce Refer further to the General Conditions These are...

Page 22: ...ST 300 Installation Service and User Manual 22...

Page 23: ...ing clearance 25 Packaging 25 Disposal 25 General specifications 26 Dimensions 26 Installation 29 Installation diagram 29 Water connections 29 Filling and Draining 31 Filling 31 Draining 32 Maintenanc...

Page 24: ...ST 300 Installation Service and User Manual 24...

Page 25: ...ble then the tank protection cannot be guaranteed 4 Warranty For access to the storage tank it is recommended that the following clearances are observed around the anode connection 100 cm around the s...

Page 26: ...odes 1 1 7 Dimensions Dimensions Unit ST 300 A Total height mm 1650 D Diameter mm 750 M Height cold water inlet mm 110 N Height warm water outlet mm 1460 P Height inspection opening mm 280 R Height co...

Page 27: ...ST 300 Installation Service and User Manual 27 Front sectional view of the appliance IMD 1281 R0...

Page 28: ...ST 300 Installation Service and User Manual 28...

Page 29: ...vessel mandatory A cold water supply B hot water supply C circulation pipe IMD 1285 R0 2 2 Water connections 2 2 1 Warning The installation should be carried out by a competent person in compliance w...

Page 30: ...ervicing Circulation pipe See C in the installation diagram 2 1 Installation diagram If an immediate flow of hot water is required at draw off points a circulation pump can be installed This improves...

Page 31: ...irculation pump 6 2 Close the drain valve 9 3 Open the nearest hot water draw off point 14 4 Open the stop valve 4 on the cold water side A so that cold water flows into the water heater 5 Completely...

Page 32: ...Service and User Manual 32 3 2 Draining 1 Close the stop valve 4 between the cold water head tank and the cold water inlet A 2 Open the drain valve 9 3 Bleed the water heater or installation so that i...

Page 33: ...scharge out 2 Check the drainage pipes from the discharge points of all valves and remove any scale deposits that may be present 3 Drain the storage tank Water side maintenance consists of descaling a...

Page 34: ...oid damage to the tank tighten the bolts that fasten the lid with a torque no greater than 50 Nm Use suitable tools for this Checking anodes Anodes ensure the protection of the tank by sacrificing the...

Page 35: ...tructions for the specific model and the relevant government and local authority installation and building codes rules and regulations in force at the time of installation b The storage tank remains i...

Page 36: ...A O Smith pursuant to the specified warranty are limited to free delivery from the warehouse of the replacement assemblies parts or storage tank respectively Shipping labour installation and any othe...

Page 37: ...nsable des r clamations de tiers li es une utilisation inad quate autre que celle mentionn e dans ce manuel d instructions et conform ment aux Conditions g n rales d pos es aupr s de la Chambre de com...

Page 38: ...ST 300 Notice d installation Mode d emploi Notice d entretien 38...

Page 39: ...41 Espace de travail 41 Emballage 41 limination 41 Donn es g n rales 42 Dimensions 42 Installation 45 Sch ma de raccordement 45 Raccordement hydraulique 45 Remplissage Vidange 47 Remplissage 47 Vidang...

Page 40: ...ST 300 Notice d installation Mode d emploi Notice d entretien 40...

Page 41: ...ications indiqu es dans le tableau la protection de la cuve ne pourra plus tre garantie 4 Garantie En ce qui concerne l accessibilit de l appareil il est recommand de tenir compte des distances minima...

Page 42: ...1 1 7 Dimensions Dimensions Unit ST 300 A Hauteur totale mm 1650 D Diam tre mm 750 M Hauteur de l alimen en eau froide mm 110 N Hauteur de la sortie d ean chaude mm 1460 P Hauteur de regard de nettoya...

Page 43: ...ST 300 Notice d installation Mode d emploi Notice d entretien 43 Vue de frontale des appareils IMD 1281 R0...

Page 44: ...ST 300 Notice d installation Mode d emploi Notice d entretien 44...

Page 45: ...ntation en eau froide B sortie d eau chaude C conduit de circulation bouclage ECS IMD 1284 R0 2 2 Raccordement hydraulique 2 2 1 Avertissement L installation doit tre r alis e par un installateur agr...

Page 46: ...roide pour l entretien 4 Si une conduite de circulation est n cessaire continuez avec le montage d une conduite de circulation 2 2 3 Conduite de circulation Sinon montez alors l ecrou d tanch it avec...

Page 47: ...int de puisage le plus proche 4 Ouvrez le robinet d arriv e du groupe de s curit 2 pour faire entrer de l eau froide dans l appareil 5 Remplissez l appareil enti rement L appareil est rempli quand un...

Page 48: ...d entretien 48 3 2 Vidange Fermez la vanne d arr t dans la conduite d eau chaude 1 Fermez le robinet d arriv e du groupe de s curit 2 2 Ouvrez le robinet de vidange 3 Purgez l appareil ou l installat...

Page 49: ...uniforme 2 V rifiez les conduites d evacuation des soupapes de trop plein er liminez les restes de calcaires pr sents 3 Vidangez l appareil L entretien du c t eau consiste d tartrer et nettoyer le r s...

Page 50: ...iter tout dommage au r servoir les boulons doivent tre viss s avec un couple de 50 Nm maximum Utilisez cet effet l outillage adapt Contr le des anodes Les anodes assurent la protection du r servoir en...

Page 51: ...st install compte tenu des prescriptions d installation appliqu es par A O Smith pour un mod le sp cifique et conform ment aux arr t s prescriptions et r glements officiels en ce qui concerne les inst...

Page 52: ...Smith conformes la garantie accord e se limite la livraison gratuite de l entrep t des pi ces ou parties remplacer ou de l appareil remplacer Les frais de transport de travail d installation et autre...