is
Instruction manual SGE
85
13.3 Troubleshooting table for displayed errors
Displayed errors
Code + description
Cause
Measure
Remark
S01 (blocking error)
Open circuit from
temperature sensor T
2
at the bottom of the
tank.
Sensor is not (correctly)
connected
Connect the sensor lead to JP3
See the electrical diagram (17 "Appendices").
Damaged cable and/or
defective sensor
Replace the cable and/or sensor.
To replace the necessary parts, you must contact your installation
engineer
S02 (blocking error)
Open circuit from
sensor 1 of
temperature sensor T
1
at the top of tank
(1)
.
Sensor is not (correctly)
connected
Connect the sensor lead to JP5
See the electrical diagram (17 "Appendices").
Damaged cable and/or
defective sensor
Damaged cable and/or defective sensor
To replace the necessary parts, you must contact your installation
engineer
S03 (blocking error)
Open circuit in sensor 2
of temperature sensor
T
1
at the top of the tank
(1)
.
Sensor is not (correctly)
connected
Connect the sensor lead to JP5
See the electrical diagram (17 "Appendices").
Damaged cable and/or
defective sensor
Replace the cable and/or sensor.
To replace the necessary parts, you must contact your installation
engineer
S04 (blocking error)
Open circuit from
dummy 1
Dummy is not
(correctly) connected
Connect the dummy sensor (dummy sensor 1 and 2) leads to JP4. See the electrical diagram (17 "Appendices").
Defective dummy
Replace the dummy sensor
To replace the necessary parts, you must contact your installation
engineer
S05 (blocking error)
Open circuit from
dummy 2
Dummy is not
(correctly) connected
Connect the dummy sensor (dummy sensor 1 and 2) leads to JP4. See the electrical diagram (17 "Appendices").
Defective dummy
Replace the dummy sensor
To replace the necessary parts, you must contact your installation
engineer
Summary of Contents for SGE - 40
Page 7: ...4 Instruction manual SGE gis ...
Page 11: ...Contents 8 Instruction manual SGE ...
Page 51: ...Conversion to a different gas category 48 Instruction manual SGE 4 is ...
Page 59: ...Draining 56 Instruction manual SGE 6 gis ...
Page 65: ...Status of the water heater 62 Instruction manual SGE 8 gis ...
Page 69: ...Shutting down 66 Instruction manual SGE 10 gis ...
Page 83: ...Instruction manual SGE 80 is ...
Page 99: ...is Instruction manual SGE 96 ...
Page 101: ...Service interval 98 Instruction manual SGE 14 is ...
Page 110: ...Instruction manual SGE 107 is ...
Page 117: ...Instruction manual SGE 114 ...