3.4.3
Gas data
Gas data
II
2H3P
description
Unit
S
GE 40
S
GE 60
Gas category 2H: G20 - 20 mbar
Venturi injector diameter
mm
-
-
Nominal load (
gross
)
k
W
4
4,4
6
3,3
Nominal output
kW
42,8
60,4
Supply pressure
mbar
20
20
CO
2
(full load)
Vol%
9,0 + 1,0
9,0 + 1,0
Gas consumption
(*)
m
3
/h
4,2
6,0
Gas category 3P: G31 - 37/50 mbar
Venturi injector diameter
mm
6,00
6,00
Nominal load (
gross
)
k
W
4
3,5
6
2,0
Nominal output
kW
42,8
60,4
Supply pressure
mbar
37 / 50
37 / 50
Gas control valve pressure
mbar
12,0 + 2,0
12,0 + 2,0
CO
2
(full load)
Vol%
10,0 + 1,0
10,0 + 1,0
Gas consumption
(*)
kg/h
3,1
4,4
(*) Based on 1013.25 mbar and 15°C.