RESIDENTIAL

Gas Water Heaters

500 Tennessee Waltz Parkway, Ashland City, TN 37015

www.hotwater.com

ARGSS00407

MODEL

FIRST

ENERGY GALLON

BTU

BTU

RECOVERY

R

DIMENSIONS IN INCHES

APPROX.

NUMBER

HOUR

FACTOR CAPACITY

INPUT

OUTPUT

90ºF RISE

VALUE

SHIPPING

RATING

PER HOUR PER HOUR

GALLONS

A

B

C

D

E

F

G

H

WEIGHT

GALLONS

NATURAL

NATURAL

PER HOUR

(LBS.)

GPD-40L

73

.59

40

40,000 †

30,000 †

41

16

57

48-1/2

21

15

8

42

17

42

224

GPDX-50L

80

.58

50

65,000 †

47,500 †

64

16

69-1/2

61

21

15

8

54-1/2

17

54-1/2

232

GPD-75L

123

.53

75

70,000 †

53,200 †

72

16

71-1/2 61-1/2 26-1/4 15-1/2

8

54-1/2

17

54-1/2

352

GPDX-50L is supplied with 5’ of 3” ABS vent pipe and must be used for the first 5’ of the exhaust outlet vent system.

GPD-75L is supplied with 5’ of 3” CPVC vent pipe and must be used for the first 5’ of the exhaust outlet vent system.

Recovery capacity based on actual performance tests.

Water Connections – 3/4" Male on all models.

† Propane Gas – 40-Gallon: 36,000 BTU input, 27,360 BTU output.

50-Gallon: 60,000 BTU input, 43,800 BTU output.
75-Gallon: 65,000 BTU input, 49,400 BTU output.

IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS

Read and follow requirements shown in the Installation Manual for ProMax

®

Power

Direct-Vent Gas water heaters dealing with type, placement and length of vent pipe
and vent termination, as well as clearances required to provide adequate
combustion and proper ventilation.

OPTIONAL CIRCULATING LOOP CONNECTION ASSEMBLIES

Sold separately. Kit Number 900152-2 includes two extended PEX lined nipples for side
port connections. Kit Number 900260-4 is same as 900152-2, plus two
di-electric unions and 2 brass isolation valves. For use with systems that have a check
valve in the air handler or recirculating lines.

IMPORTANT:
SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING
SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER
HEATERS

OPTIONAL (DELUXE) ROUND HORIZONTAL
VENT TERMINATION KIT

Part Number 9002749

OPTIONAL (DELUXE) SQUARE HORIZONTAL
VENT TERMINATION KIT

Part Number 9003328

F

E

C

D

3" VENT

4"

11.5" MIN.

FROM TOP OF

HEATER TO

CENTER LINE

OF FLUE

1/2" GAS

CONNECTION

B A

G

H

POWER DIRECT-VENT

Maximum hydrostatic working pressure: 150 psi

70

105

130

.60

.58

.58

180000 ARGSS00407.indd   2

8/17/07   4:14:04 PM