For draining water from the water heater, following steps
needs to be followed:
1. Switch off the electric supply to the water heater.
2. Open the hot water taps until the water is not hot any
more.
3. Close cold water supply.
4. Drain the water by moving the lever of safety valve in the
direction of the arrow as indicated in the diagram. (Fig. 6)
Draining
Fig. 6 Safety valve
Caution:
Once the mounting, plumbing, discharge tube, power connection and water filling
is completed, then only the power supply should be given.
5
Caution:
Before using the water heater, make sure that it should be completely filled
with water.
Please turn off the power supply to the water heater prior to draining
the water heater.
Warning:
This water heater should not be operated with insufficient amount of water.
Failure to do so may result in damage to the water heater & injuries to the users.
This will also make the warranty null & void.
Directions for use
1. Switch on the water heater’s power supply.
The green indicator light glows.
2. Turn the thermostat knob clockwise for the
device to commence heating and change
the set temperature. A
red
light will glow.
[The set temperature increases if the
thermostat knob is turned clockwise.]
Temperature can be set in the range of
25°C to 75°C. Recommended to keep
thermostat knob notch position always in
medium
or above
level.
3. The red light’s switching off indicates the
heater has been heated to the set
temperature.
Caution:
Before using the water heater, make sure the inner tank is completely filled with
water and the power plug has been connected properly.
Fig. 7