IT 300
Installation, Service and User Manual
30
2.2.2
2.2.3
Hot Water side
See (B) in the installation diagram (2.1 "Installation diagram").
Note
Insulating long hot water pipes prevents unnecessary energy loss.
1. Optional: fit a temperature gauge (12) so you can check the temperature of the
tap water.
2. Fit the T&P valve (3).
3. Fit a stop valve (11) in the hot water outlet pipe for servicing.
Circulation pipe
See (C) in the installation diagram (2.1 "Installation diagram").
If an immediate flow of hot water is required at draw-off points, a circulation pump
can be installed. This improves comfort, and reduces water wastage.
1. Fit a circulation pump (6) of the correct capacity for the length and resistance of
the circulation system.
2. Fit a non-return valve (5) after the circulation pump to guarantee the direction of
circulation.
3. Fit two stop valves for servicing (4).
4. Connect the circulation pipe according to the installation diagram (2.1 "Installation
diagram").
Summary of Contents for IT - 300
Page 4: ...IT 300 4 ...
Page 6: ...IT 300 Installatie Service en Gebruikershandleiding 6 ...
Page 8: ...IT 300 Installatie Service en Gebruikershandleiding 8 ...
Page 12: ...IT 300 Installatie Service en Gebruikershandleiding 12 ...
Page 22: ...IT 300 Installation Service and User Manual 22 ...
Page 24: ...IT 300 Installation Service and User Manual 24 ...
Page 28: ...IT 300 Installation Service and User Manual 28 ...
Page 38: ...IT 300 Notice d installation Mode d emploi Notice d entretien 38 ...
Page 40: ...IT 300 Notice d installation Mode d emploi Notice d entretien 40 ...
Page 44: ...IT 300 Notice d installation Mode d emploi Notice d entretien 44 ...