6.3
Safety devices
Fig. Safety devices
1
4
2
3
1. Temperature sensor
2. Gas control valve
3. Air proving switch
4. Flame probe
Safety devices of the water heater:
Temperature
sensor (1)
The water heater controls the water temperature
using a temperature sensor:
-
T < 5 ºC, frost protection is activated.
-
T > 90 ºC, max. temperature.
-
T > 97 ºC, for extra safety.
Gas control valve (2)
The gas control valve controls the gas supply to
the burner.
Air proving switch (3)
The air proving switch guarantees the air supply
differential during pre-purging.
Flame probe (4)
The flame probe detects if there is a flame in the
burner.
Safety devices of the installation:
Expansion vessel
The expansion vessel
stores temporarily
expansion water to
keep the pressure in
the installation at the
right level.
Expansion valve
The expansion valve
prevents excessive
pressure in the tank of
the water heater.
Pressure-reducing valve
The pressure-reducing
valve reduces the
water mains pressure,
if necessary.
Temperature and
pressure relief valve
(T&P valve)
(1)
The T&P valve prevents
excessive pressure and
temperature in the
tank.
1 - All installations have a T&P valve connection. A T&P valve is mandatory for unvented installations.
Note
This manual only discusses unvented installations.
n
0312266_INNOVO_UKUK_
V5.1, 2022-07-12
33
Summary of Contents for Innovo IR 12-160
Page 6: ...6 ...
Page 13: ...User part 0312266_INNOVO_UKUK_V5 1 2022 07 12 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V5 1 2022 07 12 27 ...
Page 28: ...28 User part ...
Page 36: ...36 Installation Maintenance and Service part ...
Page 56: ...56 Installation Maintenance and Service part ...
Page 58: ...58 Installation Maintenance and Service part ...
Page 70: ...70 Installation Maintenance and Service part ...
Page 83: ...0312266_INNOVO_UKUK_V5 1 2022 07 12 83 ...
Page 87: ...13 4 Electrical wiring diagram 0312266_INNOVO_UKUK_V5 1 2022 07 12 87 ...
Page 89: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V5 1 2022 07 12 89 ...
Page 90: ......
Page 91: ......
Page 94: ...92 Installation Maintenance and Service part ...