Figure 6
Mounting the Water Heater
Before locating the position for
installation of the water heater, make sure
that there is sufficient clearance between
the ceiling and the side wall.
6HOHFWDSODFHWRPRXQWZDWHUKHDWHU
vertically, with water connection at the
bottom.
ZDWHUKHDWHUPXVWEHORFDWHGZLWKLQ
3-1/2 ft. (approx.) from a grounded
230V electrical outlet.
Make sure that the wall can withstand
at least twice the weight of the water
heater when completely filled with
water.
Figure 7
Figure 8
8VHDGULOOELWZLWKGLDPHWHURIPP
to drill 2 holes at least 90 mm deep in
the wall (Fig. 8 : Step 3). The two holes
should be aligned horizontally. The
horizontal distance between the 2 holes
should be 73.6 mm (Fig. 8 : Step 2).
,QVHUWWKH([SDQVLRQ$QFKRUVLQWRWKH
holes (Fig. 9 : Step 1).
3DQJLQJVFUHZVRYHUWKH
expansion anchors and tighten the
Hanging Screws by rotating it till it gets
fixed steadily (Fig. 9 : Step 2).
Figure 9
Solid
Concrete
Wall
False
Wall
Expansion
Anchors
Hole
Concrete
Wall
Concrete
Wall
1
Hanging
Screws
2
73.6 mm
1
2
3
Hole
Concrete
Wall
90 mm
73.6 mm
Drilling
Tool
water heater
Ceiling
Wall