2.
Setting up Hot Water Function
2.1.Turn on the hot water switch at the back of the unit.
2.2.When the switch is on, “Hot Water/Lockout” lamp will be on.
2.3.After hot water function starts to work, it takes 30 mins to get
sufficiently heated wate . Wait for 30 minutes and after that hot water
intake is possible (at first)
2.4.At the first operation, dump 20 liters water before start to use the
unit.
2.5.After Hot Water Function is on, the unit will automatically control
the hot water temperature and keep it between 83-85 C.
WARNING:
While plugging in, if the Hot Water Switch was on, then
the device will emit a thermostat. In such a case thermostat should be
reset. During reset the device should not be connected to the pow er
supply. Otherwise there a risk of electric shock.
NOTE:
It is possible to save energy by turning off hot water switch and
take room temperature water in summer time.
3. Dispensing Hot Water from Frezya 600S
3.1. To intake hot water, first press the Hot Safety Button then press
the hot water lever.
3.2. To stop dispensing Hot Water, pull your hand away from the
hot water lever.
4. Setting up Cold Water Function
4.1.Turn on the cold water switch on the rear of the unit.
4.2.When the switch is on, “Cold Water/Lockout” lamp will be on.
4.3.After cold water function starts to work, it takes 90 mins to get
sufficiently cooled wate . Wait for 90 minutes and after that hot water
intake is possible (at first)
4.4.At the first operation, dump 20 liters water before start to use the
unit.
4.5.After Cold Water Function is on, the unit will automatically control
the cold water temperature and keep it between 4-12°C.
NOTE:
It is possible to save energy by turning off cold water switch and
take room temperature water in winter time.
To flush Alkaline filter, turn off the water connection to the tank and flush
water for at least 10 minutes until the water has no bubbles, white or
black carbon particles.
WARNING:
During the start-up even the filters are flushed, initial 20
liters of water should be flushed and not consumed.
WARNING:
Municipalities pump air to release pressure from the
plumbing lines.
This air can travel into the reverse osmosis unit within the inlet water.
You can sometimes receive white or bubbly water from your unit.
This is not any chlorine or limescale residue or any kind of technical
malfunction.
Water will be normal after a few minutes.