23
The Economy Set Point is the water temperature the control
system maintains during programmed Economy Mode
time periods. “Economy Set Point” is displayed instead of
“Operating Set Point” and “Economy Mode” appears beneath
the current time on the Desktop Screen during Economy
Mode time periods.
current time
Seven Day 24 hr clock. Use this menu item to set the current time
and day of the week. Current day and time are not set from the
factory. “Clock Not Set” will be displayed on the Desktop until the
time/day has been initially set. Note: the time will not self adjust for
Daylight Savings time.
heater In economy Mode
Displays whether the control system is currently operating in
Economy Mode or not.
daily operating Mode (sun - Mon - tue - wed - thu - fri - sat)
Seven daily sub menus are listed at the bottom of the Economy
Mode Setup menu. There are 3 Operating Modes in each sub menu;
“Normal Operation All Day” - “Economy Mode All Day” and “Normal
Operation Between.” Only one Operating Mode can be active, the
factory default is Normal Operation All Day.
Normal Operation All Day:
When this operating mode is active the
normal Operating Set Point is used for the entire day.
Economy Mode All Day:
When this operating mode is active the
Economy Set Point is used for the entire day.
Normal Operation Between:
When this operating mode is active
there will also be start and stop times to program. The normal
Operating Set Point is used between the programmed start and stop
times and the Economy Set Point will be in effect during the rest of
the day. There is one start time and one stop time event per day.