SAFE INSTALLATION, USE AND SERVICE............................2

GENERAL SAFETY..................................................................3

INTRODUCTION ......................................................................4

 

Preparing for the Installation

...............................................4

TABLE OF CONTENTS ............................................................4

TYPICAL INSTALLATION .........................................................5

LOCATING THE NEW SOLAR WATER HEATER ....................6

 

Facts to Consider About the Installation

 .............................6

 

Insulation Blankets

 .............................................................6

INSTALLING THE NEW SOLAR WATER HEATER ............6-11

 

Local Codes

........................................................................6

 

Temperature-Pressure Relief Valve

 .................................6-8

 

Closed System/Thermal Expansion

 ...................................8

 

Locating the Solar Water Heater

 ........................................8

 

Water Piping

 ..................................................................8-10

 

Filling the Solar Water Heater with Water

 .........................10

 

T&P Valve and Pipe Insulation (Selected Models)

 ...........10

 

Wiring of Element

 ........................................................10-11

 

Thermostat

 ....................................................................... 11

 

Tank Sensor

...................................................................... 11

TABLE OF CONTENTS

Thank You

  for  purchasing  this  solar  water  heater.    Properly 

installed  and  maintained,  it  should  give  you  years  of  trouble 

free service.
Abbreviations Found In This Instruction Manual:
•  ANSI - American National Standards Institute
•  ASME - American Society of Mechanical Engineers
•  AHRI - Air-Conditioning, Heating, and Refrigeration Institute 
•  NEC - National Electrical Code
•  NFPA - National Fire Protection Association
•  UL - Underwriters Laboratories Inc.
•  CSA - Canadian Standards Association

PREPARING FOR THE INSTALLATION 

 

1.  Read the “General Safety” section of this manual first and then 

the entire manual carefully.  If you don’t follow the safety rules, 

the solar water heater will not operate properly.  It could cause 

DEATH, SERIOUS BODILY INJURY,  AND/OR PROPERTY 

DAMAGE.

 

This  manual  contains  instructions  for  the  installation, 

operation, and maintenance of the electric water heater.  It also 

contains warnings throughout the manual that you must read 

and understand.  All warnings and all instructions are essential 

to the proper operation of the water heater and your safety.  

READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO 

INSTALL OR OPERATE THE SOLAR WATER HEATER.

2.  The installation must conform with these instructions and the 

local code authority having jurisdiction and the requirements of 

the power company. In the absence of local code requirements 

follow  NFPA-70,  the  National  Electrical  Code  (current 

edition), which may be ordered from: National Fire Protection 

Association, 1 Batterymarch Park, Quincy, MA 02269.

3.  If after reading this manual you have any questions or do not 

understand any portion of the instructions, call the local utility 

or the manufacturer whose name appears on the rating plate.

4.  Carefully  plan  your  intended  placement  of  the  water 

heater.  INSTALLATION  OR  SERVICE  OF  THIS  WATER 

HEATER  REQUIRES  ABILITY  EQUIVALENT  TO 

THAT OF A LICENSED TRADESMAN IN THE FIELD 

INVOLVED. PLUMBING AND ELECTRICAL WORK 

ARE  REQUIRED.

  Examine the location to ensure the water heater complies with 

the “Facts to Consider About the Location” section in this manual.

5.  For California installation this water heater must be braced, 

anchored,  or  strapped  to  avoid  falling  or  moving  during 

an  earthquake.    See  instructions  for  correct  installation 

procedures.    Instructions  may  be  obtained  from  California 

Office of the State Architect, 400 P Street, Sacramento, CA 

95814.

6.  Massachusetts Code requires this water heater to be installed 

in  accordance  with  Massachusetts  248-CMR  2.00:  State 

Plumbing Code and 248-CMR 5.00. 

INTRODUCTION

OPERATION ...........................................................................12

 

Temperature Regulation

 ...................................................12

 

Temperature Settings

 .......................................................12

 

Temperature Adjustment

...................................................12

FOR YOUR INFORMATION ...................................................13

 

Thermal Expansion

...........................................................13

 

Strange Sounds

 ................................................................13

 

Water Odor

 .......................................................................13

 

“Air” in Hot Water Faucets

 ................................................13

 

High Temperature Shut Off System

 ..................................13

MAINTENANCE ................................................................14-15

 

Draining & Flushing

 ..........................................................14

 

Element

 ............................................................................14

 

Heating Element Replacement

 .........................................14

 

Thermostat Removal / Replacement

 ................................14

 

Anode Rod Inspection

 ......................................................15

 

Temperature-Pressure Relief Valve Operation

 .................15

 

Water Heater Sounds

 .......................................................15

REPAIR PARTS ......................................................................16

 

Repair Parts Schedule

......................................................16

Summary of Contents for Cirrex SUN-80

Page 1: ...D WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOUARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER I...

Page 2: ...ey relate to the installation of electric water heaters The service agency must have a thorough understanding of the water heater Instruction Manual SAFE INSTALLATION USE AND SERVICE Your safety and t...

Page 3: ...33 GENERAL SAFETY...

Page 4: ...NG TO INSTALL OR OPERATE THE SOLAR WATER HEATER 2 The installation must conform with these instructions and the local code authority having jurisdiction and the requirements of the power company In th...

Page 5: ...s are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon con...

Page 6: ...ect to insulation and standby loss requirements making an insulation blanket unnecessary Should you choose to apply an insulation blanket to this heater you should follow these instructions below Fail...

Page 7: ...locked or reduced in size under any circumstances Excessive length over 30 feet 9 14 m or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve No valve or...

Page 8: ...event this condition a properly sized thermal expansion tank should be installed in the cold water supply to the water heater Failure to install a properly sized expansion tank in a closed system will...

Page 9: ...water taps used by these people or at the water heater Valves for reducing point of use temperature by mixing cold and hot water are also available Consult a Qualified Installer or Service Agency Fol...

Page 10: ...heater until a constant flow of water runs out an opened hot water faucet This will let out air in the solar water heater and the piping Close the faucet and solar loop air vent after all air has been...

Page 11: ...gth in any ground return path does not exceed 6 feet 1 8 m The circuit conductors contained therein are protected by overcurrent devices rated at 20 amperes or less The conduit or tubing is terminated...

Page 12: ...hot water for dishwashers The thermostat is factory set at its lowest position which approximates 120 F 49 C Hot and is adjustable if a different water temperature is desired Read all warnings in this...

Page 13: ...e corrosion protective action of the anode Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then chlorinating the wat...

Page 14: ...the thermostat 4 Disconnect the electrical wires from the heating element s by loosening the screws Figure 11 Remove the screw in element s by turning the element s counterclockwise with a 1 1 2 inch...

Page 15: ...hould be replaced NOTE Whether re installing or replacing the anode rod check for any leaks and immediately correct if found In replacing the anode 1 Turn off power to the water heater 2 Shut off the...

Page 16: ...Outlet 9006827005 3 Primary Dip Tube 9002549005 4 Element w Gasket 9003950115 5 Thermostat Bracket 9003898215 6 Thermostat w High Limit 9007623015 7 Terminal Cover 9003914015 8 Access Panel 9003900005...

Page 17: ...1717 NOTES...

Page 18: ...18 NOTES...

Page 19: ...1919 NOTES...

Page 20: ...20...