12.4 Gas details
Description
Unit
BTL 85
BTL 100
Gas category 2H (G20)
Diameter main orifice
mm
2.75
3.00
Diameter orifice pilot burner
mm
2 x 0.27
2 x 0.27
Nominal load
(Gross)
kW
22.1
21.0
Nominal output
kW
16.8
16.6
Supply pressure
mbar
20.0
20.0
Burner pressure
mbar
12.2
9.0
Gas consumption
(1)
m
3
/h
2.1
2.0
NO
x
-emission
mg/kWh
GCV
22
30
Mass flow rate flue gases
(nominal load)
kg/h
74
72
Flue gas temperature
(nominal load)
°C
142
125
Gas category 3+ (G30)
Diameter main orifice
mm
1.45
1.45
Diameter orifice pilot burner
mm
2 x 0.16
2 x 0.16
Nominal load
(Gross)
kW
18.3
16.2
Nominal output
kW
14.3
13.1
Supply pressure
mbar
30.0
30.0
Burner pressure
mbar
-
-
Gas consumption
(1)
kg/h
1.3
1.2
NO
x
-emission
mg/kWh
GCV
13
15
Mass flow rate flue gases
(nominal load)
kg/h
73
71
Flue gas temperature
(nominal load)
°C
142
125
Gas category 3+ (G31)
Diameter main orifice
mm
1.45
1.45
0313126_BTL_UKUK_V1.1, 30-11-2018