22
3.2 Fault overview
Fault
Possible cause
corrective action
Gas smell
If you smell gas you should immediately close the
main gas tap, you should not fight any fire or switch
on light. electrical switches or bels. Open windows
and immediately contact your installer or the local
gas company
Heater is off or does
not ignite
Burner automat is in lock condition
Reset burner automat with the RESET button on
the top of the collumn
Blocked chimney
Contact your installer to investigate the
cause and rectify it
Overheat thermostat is engaged
Cool down the water in the equipment and adjust
the water temperature to a lower setting (60 °C).
Reset the safety thermostat using the RESET
button.
Gas supply shut off
Open the inlet gas valve
Insufficient hot water,
or none at all
Temperature set too low
Set water temperature to higher valvue
(60 °C recommended)
Thermal Reflux Safeguard has shut
down the heater
After resetting the TRS activate the heater.
If this occurs regularly, call your installer
Overheat thermostat is engaged
Cool down the water in the equipment and adjust
the water temperature to a lower setting (60 °C).
Reset the safety thermostat using the RESET
button.
Supply of hot water exhausted
Reduce hot water use. Give the heater
time to heat the water
Unindentifiable cause
Switch off the elactricity to the heater, close
the inlet gas valve and call your installer
Explosive ignition
Wrong inlet gas pressure and/or burner
pressure
Set the correct inlet pressure and/or burner
pressure
Dirty injectors
Clean injectors
Poor flame image
Wrong inlet pressure and/or burner
pressure
Set the correct inlet pressure and/or burner
pressure
Water leakage
Condensation of (flue) gasses
See chapter “Condensation”
Leakage from other water heater or
pipes in the vicinity
If possible trace the cause and/or call your
installer