10
1.3.2 Technical data
device category: II
2H3+
*
Gas consumption at 1013,25 mbar and 15 °C
**
For a leak proof sealed connection European coupling pieces can be used on the NPT
connection nipples with a pipe thread of ISO 228/1
Description
unit
BTI 65
DATA nATuREL GAs G20 - 20 mbar
Nominal capacity
kW
12.7
Nominal load (gross)
kW
18.1
Supply pressure
mbar
20
Burner pressure
mbar
12.0
Gas consumption *
m
3
/h
1.7
Diameter main orifice
mm
3.40
Diameter pilot orifice
mm
0.56/0.41
Heating time
∆
T= 45K
min
45
DATA BuTAnE G30 - 28/30 mbar
Nominal load (gross)
kW
17.2
Nominal capacity
kW
12.3
Supply pressure
mbar
30
Gas consumption *
kg/h
1.3
Diameter main orifice
mm
1.90
Diameter pilot orifice
mm
0.23
DATA PROPAnE G31 - 37 mbar
Nominal heat input (gross)
kW
16.4
Output
kW
11.7
Inlet pressure
mbar
37
Gas consumption *
kg/h
1.2
Diameter main orifice
mm
1.90
Diameter pilot orifice
mm
0.23
GEnERAL
Storage capacity
liters
178
Water connections**
-
3
/
4
"-14NPT
Gas connection
-
Rp
1
/
2
Drain valve
-
3
/
4
"-14NPT
Anode
-
3
/
4
"-14NPT
T&P plug
-
3
/
4
"-14NPT
Maximum operating pressure
bar
8
Empty weight
kg
93
Summary of Contents for BTI - 65