background image

NEED HELP? GIVE US A CALL

 833.232.9711

To clean your filter unit, wipe down  
the exterior with a damp cloth. 

Once filters are at 95% capacity (about  
every 6 months), the battery alarm will  
sound and flash red when water is  
flowing and will continue for 15 seconds  
once water is turned off. Change the  
battery every time you replace your filters.  
The battery is included with the filter 
replacement cartridges.

Safeguards

•  Use only cold water with filter.

•  If you experience a hose connection  
  leak, disconnect and re-seat the hose.

Do not use with water that is microbiologically 
unsafe or of unknown water quality without 
adequate disinfection before or after the 
system. Systems certified for cyst reduction 
may be used on disinfected waters that may 
contain filterable cysts.

CARE AND MAINTENANCE

4

AOW-2000

Replacement cartridge AOW-2000-R

Rated service flow .5gpm (1.89 lpm)

Max capacity 500 gal (1892 liters)

Min working pressure 20 psi (137 kPa)

Max working pressure 80 psi (551 kPa)

Min operating temperature 40° F (4.44° C)

Max operating temperature 90° F (32.22° C)

CARE AND MAINTENANCE

5

Performance Data Sheet for the A. O. Smith Under Counter Water Filter

Models

Replacement

Operating pressure range Rated capacity

Operating temp. range Rated flow

AOW-2000 AOW-2000-R

20-80 psi 

137-551 kPa

500 gallons 

1892 Liters

40-90° F   

4.44-32.2° C

.05 gpm 

1.89 lpm

Manufactured by: A. O. Smith Corporation

    11270 West Park Place    |    Milwaukee, WI 53224    |    833.232.9711

Organic chemicals included by surrogate testing

VOCs  
(by surrogate testing  
using chloroform)  

Drinking 
water 
regulatory 
level (MCL/
MAC) mg/L

Influent/
Unfiltered

Effluent/
Filtered

Percent 
Reduction

alachlor 

0.002

0.050

0.001

>98%

atrazine

0.003

0.100 

0.003

>97%

benzene

0.005

0.081 

0.001

>99%

carbofuran

0.04

0.190 

0.001

>99%

carbon tetrachloride

0.005

0.078

0.0018

98%

chlorobenzene

0.1

0.077 

0.001

>99%

chloropicrin

0.015

0.0002

99%

2,4-D

0.07

0.110

0.0017

98%

dibromochloropropane (DBCP)  0.0002

0.052 

0.00002

>99%

o-dichlorobenzene

0.6

0.080 

0.001

>99%

p-dichlorobenzene

0.075

0.040 

0.001

>98%

1,2-dichloroethane

0.005

0.088

0.0048

95%

1,1-dichloroethylene

0.007

0.083 

0.001

>99%

cis-1,2-dichloroethylene

0.07

0.170   

0.0005

>99%

trans-1,2-dichloroethylene

0.1

0.086 

0.001

>99%

1,2-dichloropropane

0.005

0.080 

 0.001

>99%

cis-1,3-dichloropropylene

— 

0.079 

0.001

>99%

dinoseb

0.007

0.170

0.0002

99%

endrin

0.002

0.053

0.00059

99%

ethylbenzene

0.7

0.088 

0.001

>99%

ethylene dibromide (EDB) 

0.00005

0.044 

0.00002

>99%

haloacetonitriles (HAN)
bromochloroacetontrile

0.022

0.0005

98%

dibromoacetontrile

0.024

0.0006

98%

dichloroacetontrile

0.0096

0.0002

98%

trichloroacetontrile

0.015

0.0003

98%

haloketones (HK)
1,1-dichloro-2-propanone

0.0072

0.0001

99%

1,1,1-trichloro-2-propanone

0.0082

0.0003

 96%

heptachlor (H-34, Heptox)

0.0004

0.025 

0.00001

>99%

heptachlor epoxide

0.0002

0.0107

0.0002

98%

hexachlorobutadiene

0.044 

0.001

>98%

hexachlorocyclopentadiene

0.05

0.060 

0.000002 >99%

lindane

0.0002

0.055 

0.00001

>99%

methoxychlor

0.04

0.050 

0.0001

>99%

pentachlorophenol

0.001

0.096 

0.001

>99%

simazine

0.004

0.120 

0.004

>97%

styrene 

0.1

0.150 

0.0005

>99%

1,1,2,2-tetrachloroethane 

0.081 

0.001

>99%

tetrachloroethylene

0.005

0.081 

0.001

>99%

toluene

1

0.078 

0.001

>99%

2,4,5-TP (silvex) 

0.05

0.270

0.0016

99%

tribromoacetic acid

0.042 

0.001

>98%

1,2,4-trichlorobenzene

0.07

0.160 

0.0005

>99%

1,1,1-trichloroethane

0.2

0.084

0.0046

95%

1,1,2-trichloroethane

0.005

0.150 

0.0005

>99%

trichloroethylene

0.005

0.180 

0.0010

>99%

trihalomethanes (THMs)

Influent/

Unfiltered

Effluent/

Filtered

Percent 

Reduction

bromodichloromethane (THM)

0.080

0.300

0.015

95%

bromoform (THM)
chloroform (THM)
chlorodibromomethane (THM)
xylenes (total)

10

0.070 

0.001

>99%

NSF/ANSI 42

Min Reduction

Overall % Reduction Results

Chlorine Reduction, Free Available

<0.5 mg/l

97.66%

Pass

Chloramine Reduction, Free Available <0.5 mg/l

97.66%

Pass

Particulate Reduction

85%

99.9%

Pass

NSF/ANSI 53

Min Reduction

Overall % Reduction Results

Cyst Live Cryptosporidium & Giardia 99.95%

>99.99%

Pass

Mercury Reduction pH 8.5

<2 ug/L

>95%

Pass

Mercury Reduction pH 6.5

<2 ug/L

>96.5%

Pass

Lead Reduction pH 6.5

<10 ug/L

>99.4%

Pass

Lead Reduction pH 8.5

<10 ug/L

>99.3%

Pass

MTBE Reduction 

<5 ug/L

86.6%

Pass

Turbidity

<0.5 NTU

99.1%

Pass

VOC Surrogate Test 

95%

99.4%

Pass

Asbestos

99%

>99%

Pass

NSF/ANSI 401 Maximum 

Concentration 

Minimum Reduction  Overall % Reduction Results

Atenolol

30 ng/L

94.2%

94.2%

Pass

Bisphenol A

300 ng/L

98.80%

98.9%

Pass

Carbamazepine 200 ng/L

98.6%

98.6%

Pass

DEET

200 ng/L

98.7%

98.7%

Pass

Estrone

20 ng/L

96.30%

96.5%

Pass

Ibuprofen

60 ng/L

95.3%

95.4%

Pass

Linuron

20 ng/L

96.6%

96.6%

Pass

Meprobamate

60 ng/L

94.7%

94.7%

Pass

Metolachlor

200 ng/L

98.6%

98.6%

Pass

Naproxen

20 ng/L

96.3%

96.4%

Pass

Nonyl phenol

200 ng/L

97.50%

97.5%

Pass

Phenytoin

30 ng/L

95.50%

95.6%

Pass

TCEP

700 ng/L

98%

98%

Pass

TCPP

700 ng/L

97.8%

97.8%

Pass

Trimethoprim

20 ng/L

96.7%

96.7%

Pass

NSF P473

Influent challenge 
concentration

Maximum 
permissible 
concentration

Overall % reduction Results

Perfluorooctanoic 

acid (PFOA) & 

Perfluorooctane 

sulfonate (PFOS)

1.5 ±10% ug/L

0.07 ug/L

96 %

Pass

System Tested and Certified by NSF International against NSF/
ANSI Standard 42, 53 & 401 and conforms to NSF protocol 
P473 for reduction of claims specified on the Performance 
Data Sheet and at www.nsf.org.

For use with municipally treated water only. Do not use with 
water that is microbiologically unsafe or of unknown water 
quality without adequate disinfection before or after the system.

Filter is only to be used  
with cold water. 

Filter usage must comply  
with all state and local laws.

Testing was performed 
under standard laboratory 
conditions, actual 
performance may vary. 

Systems certified for cyst 
reduction may be used on 
disinfected waters that may 
contain filterable cysts. 

See owner’s manual for general 
installation conditions and 
needs plus manufacturer’s 
limited warranty.

• All contaminants reduced by this filter are listed. 
• Not all contaminants listed may be present in your water. 
• Does not remove all contaminants that may be present in tap water.

Testing Performed under NSF/ANSI Standards 42 and 53 and in accordance with the California Department of Health Services Drinking Water Treatment 

Device Program. This system has been tested according to NSF/ANSI 42, 53, 401 & P473 for reduction of the substances listed below. The concentration 

of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the 

system, as specified in NSF/ANSI 42, 53, 401 & P473.

Remove  

each sump 

from the 

manifold  

by hand.

Place wrench  

over sump  

top and  

slide down.

Continue turning 

counterclockwise.

Remove top  

and filter.

WARNING 

Do not use tools 

to remove or tighten sumps. 

Over-tightening can cause 

damage and result in leaking. 

HAND TIGHTEN ONLY.

Turn wrench 

to right; 

sump to 

left.

Summary of Contents for AOW-2000

Page 1: ...NER S MANUAL Use this owner s manual to reference installation troubleshooting and filter replacement information If you need help or have a question we ve got you covered Give us a call at 833 232 97...

Page 2: ...AOW 2000 2 STAGE UNDER SINK Sistema bajo el fregadero de 2 etapas Owner s Manual El manual del proprietario...

Page 3: ...ve us a call at 833 232 9711 BOX CONTENTS 1 Tools recommended for installation Variable speed drill w 7 32 bit Adjustable wrench Measuring tape Bucket Phillips head screwdriver Hammer Faucet may be mo...

Page 4: ...ALLATION GUIDE Connect supply lines Insert tubing from tee fitting into the inlet side and insert tubing from faucet into the outlet side Use diagram to mark tubing depth to ensure they are completely...

Page 5: ...1 1 trichloroethane 0 2 0 084 0 0046 95 1 1 2 trichloroethane 0 005 0 150 0 0005 99 trichloroethylene 0 005 0 180 0 0010 99 trihalomethanes THMs Influent Unfiltered Effluent Filtered Percent Reductio...

Page 6: ...e covered product and send it to you upon payment of 9 50 for shipping and handling per incident How to get service To receive service under this warranty you must contact A O Smith at 833 232 9711 or...

Page 7: ...espu s el collar n blanco para conectar la manguera de salida a la base de la llave Coloque el inserto blanco en el extremo del tubo Presione el tubo contra la base de la llave y deslice la tuerca y e...

Page 8: ...pliegues 1 2 3 Profundidad para insertar las tuber as de 2 pasos El diagrama tiene la dimensi n real 6 10 8 Fije cada sumidero en la parte posterior de la carcasa de la unidad Alinee los puntos de con...

Page 9: ...ca en las normas NSF ANSI 42 53 401 y P473 13 Hoja de datos de rendimiento del filtro de agua para debajo del mostrador de A O Smith Modelos Repuesto Rango de presi n de funcionamiento Capacidad nomin...

Page 10: ...taminant reduction performance system damage or failure Use of parts from other manufacturers will also void your warranty Please visit www aosmith com wholesale for replacement parts Installation mus...

Reviews: