1. Identify drain outlet location.
STEP 5
Install Drain Connector
HOT
COLD
2. Remove protective cover from
back of foam seal
(N)
and punch
out the center hole.
3. Align holes and attach foam seal to
front plate of drain connector
(L)
.
DRAIN PIPE
BRACKET
NEW HOLE
PRO TIP: If there is leakage from the drain bracket, loosen the bolts and slide the
bracket up so the drilled hole is at the bottom of the drain connector port.
WARNING
Ensure all electrical appliances and
outlets are turned off at the circuit breaker before
working in the cabinet area.
CAUTION
Wear safety glasses to
protect eyes when drilling.
INSTALLATION GUIDE
6
4. Use drain connector to mark drill
location on drain-line. Position
drain connector on drain pipe
above drain trap allowing room
for drilling.
5. Using a
7
⁄
32
" drill bit, drill hole into
drain pipe.
6. Securely tighten drain connector
using nuts and screws
(M)
.
WARNING:
DO NOT drill hole through
opposite side of pipe.
WARNING:
Do not install the drain connector onto the same drain pipe as the garbage disposal. If drain-line must be
installed on the same line as garbage disposal, do not use the drain connector included. A garbage disposal connector