10
GA
S
INT
AKE
CLEANOUT
T&P
DRAIN
EXHAUST
1 1/2" NPT
WATER
OUTLET
FRONT
18°
30°
45°
42°
70°
20°
TOP
RECIRC RETURN
CLEANOUT
3/4" NPT
T&P
3/4" NPT DRAIN
1 1/2" NPT
WATER INLET
52in
132.08cm
32.39cm
12-3/4in
4-3 /4in
12.07cm
58.43cm
23in
75-3/4in
192.41cm
FRONT
4" EXHAUST VENT
CONNECTION
CONNECTION
1 1/2" SUPPLY GAS
BACK
4" PVC AIR INTAKE
CONNECTION
74-1/2 in
33-1/8in
189.23cm
84.12cm
O.D.
69-1/4in
175.9cm
63 -1/8in
160.35cm
WATER
OUTLET
HEIGHT
Figure 6
7KHVHGHVLJQVFRPSO\ZLWKWKHFXUUHQWHGLWLRQRIWKH$PHULFDQ1DWLRQDO6WDQGDUGIRU*DV)LUHG:DWHU+HDWHUV9ROXPH,,,$16,=
&6$%7+DQGDUH$XWRPDWLF&LUFXODWLQJ7DQNRU$XWRPDWLF6WRUDJH:DWHU+HDWHUV%7+LV$XWRPDWLF&LUFXODWLQJ7DQNRU
$XWRPDWLF,QVWDQWDQHRXV:DWHU+HDWHU
STORAGE CAPACITIES
TABLE 2
0RGHO
86*DOORQV
Liters
$60(
6WDQGDUG
$60(
6WDQGDUG
All
119
119
ROUGH IN DIMENSIONS
GAS LINE CONNECTION SIZE
TABLE 1
02'(/
SERIES
1$785$/*$6
PROPANE GAS
BTH 300
300/301
´137
´137
BTH 400
300/301
´137
´137
BTH 500
300/301
´137
´137
7KLVWDEOHVKRZVFRQQHFWLRQVVL]HVRQO\'HSHQGLQJRQWKHLQVWDOOHGHTXLYDOHQWOHQJWK
DQGRUWKHQXPEHURIDSSOLDQFHVFRQQHFWHGWKHVXSSO\JDVOLQHVL]HPD\KDYHWREH
LQFUHDVHGEH\RQGWKHPLQLPXPUHTXLUHGVL]HVVHH*DV/LQH6L]LQJRQSDJH
RECOVERY CAPACITIES
TABLE 3
U.S. GALLONS/HR & LITERS/HR AT TEMPERATURE RISE INDICATED
0RGHO
Type of
Gas
Input
7KHUPDO
(I¿FLHQF\
°F
30°F
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
Btu/hr
kW
&
&
&
&
&
&
&
&
&
&
&
&
&
BTH 300
Natural
88
96
GPH
1164
873
698
582
499
436
388
349
317
291
269
249
Propane
LPH
4404
3303
2643
2202
1888
1652
1468
1321
1201
1101
1016
944
BTH 400
Natural
117
95
GPH
1535
1151
921
767
658
576
512
460
419
384
354
329
Propane
LPH
5810
4357
3486
2905
2490
2179
1937
1743
1585
1452
1341
1245
BTH 500
Natural
146
95
GPH
1919
1439
1151
959
822
720
640
576
523
480
443
411
Propane
LPH
7263
5447
4358
3631
3113
2724
2421
2179
1981
1816
1676
1556
GAS PRESSURE REQUIREMENTS
TABLE 4
02'(/
0$1,)2/'35(6685(
0,1,0806833/<35(6685(
0$;,0806833/<35(6685(
1$785$/*$6
PROPANE GAS
1$785$/*$6
PROPANE GAS
1$785$/*$6
PROPANE GAS
BTH 300
´:&N3D
´:&N3D
:&N3D
´:&N3D
´:&N3D
´:&N3D
BTH 400
´:&N3D
´:&N3D
:&N3D
´:&N3D
´:&N3D
´:&N3D
BTH 500
´:&N3D
´:&N3D
:&N3D
´:&N3D
´:&N3D
´:&N3D
* The manifold pressure is the factory setting and is not adjustable.
$QHJDWLYHSUHVVXUHZLOOEHVHHQZLWKMXVWWKHEORZHUUXQQLQJZLWKRXWWKH*DV&RQWURO9DOYHRSHQ
MINIMUM SUPPLY GAS LINE SIZE
TABLE 5
02'(/
1$785$/*$6
PROPANE GAS
BTH 300
1 1/4" NPT
1 1/4" NPT
BTH 400
1 1/4" NPT
1 1/4" NPT
†BTH 500
1 1/2" NPT
1 1/4" NPT
1RWHWKDW%7+QDWXUDOJDVPRGHOVUHTXLUHDPLQLPXPVXSSO\JDVOLQHVL]H'HSHQGLQJRQWKHLQVWDOOHGHTXLYDOHQWOHQJWKDQGRUWKHQXPEHURIDSSOLDQFHVFRQQHFWHGWKHVXSSO\JDV
OLQHVL]HPD\KDYHWREHLQFUHDVHGEH\RQGWKHPLQLPXPUHTXLUHGVL]HVVKRZQLQWKLVWDEOHVHH*DV/LQH6L]LQJRQSDJH
INSTALLATION CONSIDERATIONS
Summary of Contents for 500