background image

Residential Gas Water Heaters

B

A

F

D

1/2" GAS
CONNECTION

T&P VALVE

COLD
CONNECTION

C

E

*Location for optional top-mounted 
  T&P Valve if ordered from factory.

A. O. Smith FVIR design meets or exceeds the American National Standards Institute standards 
(ANSI Z21.10.1 - 4.1 CSA Standards) that deal with the accidental or unintended ignition of  
flammable vapors, such as those emitted by gasoline. 

Feature a sealed combustion chamber with air intake filter and a flame arrestor built
into the water heater base. In addition, a thermal cutoff (TCO) device, is designed
to shut off gas flow to the burner and pilot if poor combustion is detected.

Flammable Vapor Ignition
Resistant Water Heaters

AOSRG45350

www.hotwater.com

For Technical Information and Automated Fax Service, call 800-527-1953. A. O.  Smith Corporation reserves the right to make produ ct changes or improvements without prior notice.

MODEL

NUMBER

FIRST

HOUR

RATING

GALLONS

ENERGY

FACTOR

GALLON

CAPACITY

BTU

INPUT

PER HOUR

NATURAL

RECOVERY

90ºF RISE

GALLONS

PER HOUR

FOAM

THICKNESS

(INCHES)

A

B

C

D

E

F

DRAFT

HOOD

OUTLET

APPROXIMATE

SHIPPING

WEIGHT

(LBS)

SHORT MODEL

DIMENSIONS IN INCHES

Maximum Hydrostatic Working Pressure: 150 PSI.

HOT
CONNECTION

ANODE ROD*

TALL MODELS

Page 2 of 2

SERIES 200/201

35,500

36

2

67

.62

30

GVR-30

3 or 4

June 2010R

If flammable vapors accidentally enter the 
combustion chamber, the arrestor is designed 
so flames burn off the top surface and can not 
escape down through the arrestor.

A. Industry standard thermocouple
B. Large View Port for easy burner inspection
C. 360

0

 combustion air filter

D. Thermal Cutoff (TCO) with manual reset

67

147

22

13

8

41

3 or 4

47-3/4

51-1/2

41

2

40,000

40

.62

GVRL-40

GVR-50

88

41

40,000

50

.62

22

13

8

57-1/4

61

2

50-1/4

3 or 4

165

126

   52

18

13

8

    58

61-1/2

40,000

41

2

70

.62

40

GVR-40

3 or 4

150

51-3/4

20

13

8

58-1/4

61-3/4

Recovery capacity based on actual performance tests.

Water Connections – 3/4" on all models.
† Propane Gas – 37,000 BTU input for 50 gallon models, 36,000 BTU for 40 gallon models and 32,000 BTU input for 30 gallon models.
For 10-Year Tank and 6-Year Parts Warranty, change “G” to “X” in Model Number (example: XVR-40).

Heat Trap Nipples installed on all models.
All Models are ENERGY STAR

® 

qualified.

®

SERIES

200/201

200/201

200/201

202/203

226337_AOSRG45350.indd   2

226337_AOSRG45350.indd   2

6/24/10   3:28 PM

6/24/10   3:28 PM

Reviews: