TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-

ment should be performed by qualified service personnel.  The unit should be unplugged when servicing.

Problem

Possible Cause

Corrective Action

No heat, no display, and the 

power switch indicator light is 

OFF.

Power cord is not plugged in.

Plug the power cord into the appropriate outlet.

Circuit breaker is off or has been tripped.

Reset circuit breaker, contact your maintenance person or 

Authorized Service Agency if it trips again.

No power at receptacle.

Contact your maintenance person or Authorized Service 

Agency for service.

Inoperable power cord.
Inoperable power switch.
Loose, burnt, broken wiring in the circuit.

No heat, no display, and the 

power switch indicator light is 

ON.

Inoperable Transformer.

Contact your maintenance person or Authorized Service 

agency for service.

Inoperable Control Board.
Loose, burnt, broken wiring in circuit.

Display flashes “

LO

” and the 

cabinet does not heat up.

Inoperable Solid State Relay.

Contact your maintenance person or Authorized Service 

Agency for service.

Inoperable Control Board.
Inoperable Heater(s).
Loose, burnt, broken wiring in circuit.

Display flashes “

HI

” and the 

cabinet does not heat up.

Inoperable Thermistor.

Contact your maintenance person or Authorized Service 

Agency for service.

Inoperable control Board.

Display flashes “

HI

” and the 

cabinet is very hot.

Solid State Relay contacts shorted closed.

Contact your maintenance person or Authorized Service 

Agency for service.

Inoperable Control Board.

Display flashes “

OPEN

” and the 

cabinet does not heat up.

Thermistor is disconnected or open.

Re-secure the Thermistor onto the Control Board.  If this 

problem persists, contact your maintenance person or 

Authorized Service Agency for service.

Inoperable Control Board.

Display flashes “

PO

” and the 

cabinet does not heat up.

For 120 volt units, the supply voltage is below 

100 VAC or above 135 VAC.

Contact your maintenance person or Authorized Service 

Agency for service.

For 220/240 volt units, the supply voltage is 

below 190 VAC or above 265 VAC. 
Inoperable Control Board.

Product dries out quickly.

Setpoint temperature is set too high.

Lower the Setpoint temperature.

Incorrect wattage halogen bulb(s) being used. Use only 100 watt halogen bulb(s).
Water Tray(s) do not contain water or contain 

insufficient water (for units equipped with 

Water Trays only).

Add water to the Water Trays(s) and/or remove the Water 

Tray Diffuser(s).

Display Cabinet glass is fogging 

up and/or has condensation.

Water Tray(s) contain too much water and/or 

the Water Tray Diffusers are not present (for 

units equipped with Water Trays only).

Remove excess water from the Water Tray(s) and/or install 

the Water Tray Diffuser(s).

Halogen Bulb(s) do not light up.

Bulb(s) burnt out.

Replace bulb(s)

Bulb(s) not seated properly into spring loaded 

sockets.

Remove and reinstall bulb(s) so that the ends snap into the 

socket(s).

Inoperable Resistor Assembly.

Contact your maintenance person or Authorized Service 

Agency for service.

Loose, burnt, or broken wiring in Circuit.
Inoperable Bulb Sockets(s).

Front Display Graphics does not 

light up.

Bulb(s) burnt out.

Replace Bulb(s).

Loose, burnt, or broken wiring in circuit.

Contact your maintenance person or Authorized Service 

Agency for service.

Summary of Contents for Roundup DCH-100

Page 1: ...CH 120 220 320 Owner s Manual MANUFACTURING NUMBERS 9500500 9500510 9500512 9500520 9500530 9500531 9500532 9500533 9500534 9500536 9500538 9500540 9500550 9500551 9500552 9500553 9500554 9500556 A S...

Page 2: ...ease read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the carrier immediately and file a damage claim with them Save all packing materials when filing a cl...

Page 3: ...f you experience any problems with the installation or operation of your unit contact your local Roundup Authorized Service Agency Fill in the information below and have it handy when calling your aut...

Page 4: ...rate electrical lines pro tected by fuses or a circuit breaker of the proper rating Electrical ground is required on this appli ance Do not modify the power supply cord plug If it does not fit the out...

Page 5: ...removing the glass make sure that the glass is cool room temperature USE approved cleaners marketed for glass cleaning only USE a flat surface covered with a soft cloth to place the glass on if the gl...

Page 6: ...20CF 9500510 120 1550 12 9 50 60 DCH 120CT 9500512 120 1550 12 9 50 60 DCH 200CT 9500520 120 1800 15 0 50 60 DCH 220CT 9500530 120 1800 15 0 50 60 DCH 220CT 9500531 120 1800 15 0 50 60 DCH 220CT 95005...

Page 7: ...models DCH 300 DCH 320 Three 2 1 2 63 5 mm deep full size steam table pans Two water trays at 5 quarts 4 7 liters each Temperature Ranges DCH 100 150 165 F 66 74 C DCH 120 100 165 F 38 74 C DCH 200 1...

Page 8: ...to the stated voltage on the unit specification label located at the end of the power cord Turn the Rocker Switch power On Off to OFF Connect the unit to the power supply INSTALLATION CAUTION All ele...

Page 9: ...diffuser s Figure 2 If a dry environment is desired DO NOT add water to the Water Trays If a humid environ ment is desired add water to the Water Trays as shown in Figure 2 If more humidity is desire...

Page 10: ...acement FRONT DISPLAY GRAPHICS AND BULB REPLACEMENT 1 Turn the Rocker Switch Power On Off to OFF 2 Unplug the power cord from the electrical outlet and allow the unit to cool to room temperature befor...

Page 11: ...Remove each Top Cap Assembly Figure 8 Next lift the Side Glass Panel up and forward to remove it from the glass clips 6 To reinstall position the Side Glass Panel into glass clips Push fully rearward...

Page 12: ...e models the Heated air is circulated by one or two blower motors while other models do not use blower motors Some models use water trays while other models use a crumb tray NOTE Crumb Trays Figure 1...

Page 13: ...l cabinet temperature exceeds the setpoint temperature or if the thermistor has short ed NOTE The thermistor should be 100k ohm 2 at room temperature OPEN flashes if the thermistor is OPEN or discon n...

Page 14: ...e Agency for service Inoperable Control Board Display flashes OPEN and the cabinet does not heat up Thermistor is disconnected or open Re secure the Thermistor onto the Control Board If this problem p...

Page 15: ...13 REPLACEMENT PARTS DCH 100 120 47 18 60 50 61 23 22 50 60 59 19 47 27 47 30 28 32 31 33 35 20 12 55 16 49 53 50 49 15 17 11 13 40 44 52 2 42 43 52 3 1 55 52 4 9 9 10 5 6 58 7 57 63 21 48 37 64 36 6...

Page 16: ...036 Base Hinge Assy 1 38 4030305 Heating Element 120V 1400 Watts 1 39 7000369 Thermistor Replacement Kit 1 40 0503037 Duct Access Cover 1 42 4060252 Bulb Quartz Halogen 100 Watt 1 43 4060189 Bulb Hold...

Page 17: ...12 13 REPLACEMENT PARTS DCH 200 220 53 64 46 45 53 48 54 25 26 20 58 21 24 50 18 68 12 16 56 52 15 17 11 13 35 42 43 55 41 10 58 55 50 6 4 55 40 44 2 3 7 19 52 67 31 32 33 34 30 29 68 62 14 5 22 59 1...

Page 18: ...9 4060341 Terminal Block 8 Pole 2 2 2 2 20 0504070 Retainer Glass see Note 1 2 2 2 2 21 0011718 Top Cap Assy LH see Note 1 1 1 1 1 0011717 Top Cap Assy RH see Note 1 1 1 1 1 22 2100183 Door Track Uppe...

Page 19: ...2 SS 1 1 1 1 62 040P111 Snap Bushing 2 2 2 2 63 308P105 Screw 8 32 x 1 2 SS 2 2 2 2 64 308P151 Screw 8 32 x 5 16 1 1 1 1 65 0503280 Diffuser Water Tray some models 66 0503279 Water Tray some models 6...

Page 20: ...12 13 53 46 45 12 16 56 52 15 17 11 13 42 43 55 41 9 69 58 6 4 55 40 44 2 3 7 5 1 39 70 23 7 20 58 22 24 66 53 48 54 25 5018 65 34 31 32 33 29 30 50 37 66 36 35 52 19 35 52 71 71 14 21 34 55 67a 67b...

Page 21: ...Except Mfg No 9500554 556 4000194 Blower Motor Mfg No 9500553 1 36 0200155 Magnetic Strip 2 37 5040028 Base Hinge Assy 1 38 4030304 Heating Element 120V 500 Watts 3 4030239 Heating Element 230 Volts 8...

Page 22: ...BLOCKS TERMINAL 1 2 5 4 WHT WHT WHT WHT BLK SWITCH POWER GRN YEL GRN WHT BLU BLK BRN WHT BLK WHT BLK WHT BLK DISPLAY LAMPS THERMISTOR HEATER QUARTZ LAMP BLK BLK YEL YEL YEL YEL RED BLK WHT BLK TRANSF...

Page 23: ...BLK BLK WHT GRN BLOCK 1 TERMINAL GND CORD POWER 14 GA TFE 200 18 GA TFE 200 BLOCKS TERMINAL DCH 320 230 Volt Units WHT WHT WHT BLOCKS TERMINAL WHT BLK GRN SWITCH POWER BLOCK 1 TERMINAL GND GRN YEL GR...

Page 24: ...ninety days after installation in the U S ONLY the unit will be repaired in store subject to the terms of the limited warranty by our Authorized Service Agency at no charge for parts and non overtime...

Reviews: