background image

UFC-420/440 water Filtration system

7

P/N 1010908 Rev. A 03/12

A.J. Antunes & Co.

Unpacking

  1.  Remove the system and all packing materials 

from the chipping carton.

  2.  Remove all packing materials and protective cov-

erings from the system

  3.  Remove the information packet.  To prevent any 

delay in obtaining warranty coverage, fill out and 

mail the warranty card.

nOte:  If any parts are damaged, contact antunes 

filtration technologies ImmeDIatelY at 1-800-253-

2991 or 1-630-784-1000.

equipment setup

General

When placing the unit into service, pay attention to the 

following guidelines:

  •  Make sure power to the unit is off.

  •  Do not immerse cord or plug in water.

  •  Keep cord away from heated surfaces.

electrIcal

Ensure that the line voltage corresponds to the stated 

voltage on the units specification label.  Make sure that 

the plug on the power cord from the system and the 

outlet match.  For proper operation, and to ensure the 

highest quality water from the system, make sure that 

the system is not connected to a switched electrical 

outlet.

plUmbInG

nOte:  this unit is designed to use tap water not 

to exceed 104°F (40°C).

The UFC-420 and UFC-440 systems use the following 

connections (Figure 1):

 

•  Water Inlet  

 

 

3/4” NPT

 

•  Permeate (Product Water) 

3/4” NPT

 

•  Drain   

 

 

3/4” NPT

InstallatIOn

When making a plumbing connection to the system, 

remember to use a back-up wrench on the supporting 

plumbing.  Always use a good quality, approved, pipe 

sealant or thread seal tape on pipe threads.  Be careful 

not to get the pipe sealant inside the pipe when making 

the connections.  

Do not

 over tighten the connections.  It is recommend-

ed that plastic fittings be used when connecting to the 

plastic connections of the system.  This will reduce the 

possibility of  cracking the connections due to overtight-

ening.  

If soldered plumbing is used, do not apply heat to, or 

near, the filtration system.  The use of union (o-ring 

seal) connections is highly recommended for ease of 

installation and future servicing.

sUGGesteD tOOls anD sUpplIes fOr InstallatIOn

The following tools and supplies are suggested to make 

the installation easier:

•  Screwdriver

 

•  Drill with bits

 

•  Strap wrench 

 

  (up to 6” diameter)

 

•  Tape measure

 

•  Two gallon bucket

 

•  Fresh 5 1/4% liquid 

  chlorine bleach 

 

•  Adjustable wrenches

 

•  Pipe wrenches

 

•  Level

 

•  Pipe dope or thread  

  seal tape

Summary of Contents for 9700610

Page 1: ...Water filtration system UFC 420 440 Series Owner s Manual P N 1010908 Rev A 03 12 Manufacturing Numbers 9700610 9700612 9700614 9700616 ...

Page 2: ...t arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under warranty The warranty does not extend to Damages caused in shipment or damage as result of improper use Installation of electrical service Normal maintenance as outlined in this ma...

Page 3: ...the equipment is furnished with a properly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this manual Do not use corrosive chemicals in this equipment Do not operate this equipment if it has a dam aged cord or plug if it is not working properly or if it has been damaged or dropped This equipment sho...

Page 4: ...d person This equipment is to be installed to comply with the local plumbing code and any other applicable code Water pressure must not exceed the membrane differential pressure of 45 psig 3 1 bar To reduce water pressure install a water pressure regulator and set the system inlet water pressure to 45 psi 3 1 bar Inlet Water Pressure psi Inlet Turbidity NTU Required Additional Equipment Installed ...

Page 5: ...this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Specifications Filter Cartridges Maximum Operating Pressure 3 bar 45 psi Maximum Operating Temp 40 C 104 F Trans Membrane Pressure 0 5 2 5 Bar 7 36 psi pH Range 3 10 MWCO 100 kD Sanitizing Temp 80 C 176 F Unit A Width B Depth C Height Operating Weight w water UFC 420 10 inches 254...

Page 6: ...UFC 420 440 water Filtration system 6 P N 1010908 Rev A 03 12 A J Antunes Co Specifications Figure 2 Components Components LED Display Program Button Power Cord Water Inlet Drain Permeate Product Water ...

Page 7: ...NOTE This unit is designed to use tap water not to exceed 104 F 40 C The UFC 420 and UFC 440 systems use the following connections Figure 1 Water Inlet 3 4 NPT Permeate Product Water 3 4 NPT Drain 3 4 NPT Installation When making a plumbing connection to the system remember to use a back up wrench on the supporting plumbing Always use a good quality approved pipe sealant or thread seal tape on pip...

Page 8: ...stem hold a bucket or other con tainer at the inlet water line and slowly open the inlet water valved Allow the pipe to flush until all debris is removed Permeate Line Plumbing To ensure the highest quality and safest water it is recommended that a check valve to prevent backflow be installed in the water line after the permeate connec tion This will help prevent possible contamination of the filt...

Page 9: ...gesting the protective solution may cause irrita tion of the gastrointestinal tract colic diarrhea or other similar symptoms Installation continued 8 After 15 minutes without water flow open the tap for 5 minutes to allow any trapped air to be flushed out 9 Close the tap Flushing is complete Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contamination that may...

Page 10: ...order to keep water filtering during a power outage Figure 4 LED Display Front Panel LED Display Fi Flush Interval Mode is the time between flushings and is displayed in minutes or hours Fd Flush Duration Mode is the amount of time used to flush and remove debris from filter cartridge and is displayed in seconds FL Manual Flush Mode operation solenoid is manually activated by the user Starting the...

Page 11: ...returns to Flush Interval Mode NOTE Fi times are displayed in ten minute inter vals after fifty minutes they are displayed in hours Table A Figure 7 LED Display for Flush Duration Mode Figure 8 Time Setting Fd Mode 55 Seconds Table A LED Display Settings Figure 6 Time Setting Fi Mode 22 Hours Figure 5 LED Display for Flush Interval Mode Setting Flush Duration FD 2 When Fd is displayed press and re...

Page 12: ...e intervals after fifty minutes they are displayed in hours Table B TO SET FD FLUSH DURATION MODE 1 Press and hold down start button for four seconds Release button LED will display Fd 2 When Fd is displayed Figure 9 press and release button to view current setting 3 To make a change press and hold down start button to scroll through settings release button at desired setting Figure 10 4 After ten...

Page 13: ...t button down for 6 7 seconds until the LED displays FL Figure 11 Continue holding the button down to keep the drain open Drain will remain open for as long as start button is depressed FL will flash on LED Releasing the but ton closes the drain and puts the unit back into startup mode After ten seconds if the start button is not pressed the unit automatically returns to the Flush Interval Mode Fi...

Page 14: ...en the strainer by unscrewing the cap Water will flow out of the strainer as the system drains 4 Press and hold the Start button to help drain the system 5 Reattach the cap on the strainer when the water flow stops Unplug the power cord 6 Using a strap wrench up to 6 capacity loosen the top and bottom end caps DO NOT remove the top and bottom End Caps yet 7 Disconnect the permeate port connection ...

Page 15: ...al growth in pipes Sanitize plumbing Water conditions changed Consider installing taste and odor filtration Broken capillary in Filter Cartridge Replace Filter Cartridge Flush runs continuously Drain Valve stuck open Replace rebuild the Drain Valve Controller sending continuous signal to valve Replace the controller Flush runs too long Program duration set too long Re program the unit to flush for...

Page 16: ...UFC 420 440 water Filtration system 16 P N 1010908 Rev A 03 12 A J Antunes Co Replacement parts UFC 420 440 10 9 11 16 17 16 18 15 26 27 1 28 5 2 12 22 23 4 3 24 25 19 20 UFC 420 440 ...

Page 17: ...3 Mounting Bracket Weldment UFC 420 1 0021332 Mounting Bracket Weldment UFC 440 1 12 0021455 Main Housing Weldment UFC 420 1 0021460 Main Housing Weldment UFC 440 1 15 2090122 Cartridge Filter 4 x 20 1 2090123 Cartridge Filter 4 x 40 1 16 0011606 End Cap Union Connector Assy 4 2 17 2190127 Union End Cap 4 2 18 7000405 O Ring End Cap Union 2 19 2190123 Y Strainer 3 4 NPT 1 20 2090126 Screen Y Strai...

Page 18: ...0908 Rev A 03 12 A J Antunes Co Wiring Diagram TIMER BOARD SOLENOID VALVE RED BLK T2 T3 T4 WHT BLK GND TERMINAL BLOCK GRN YEL WHT BLU BLK BRN POWER CORD NOTE ALL WIRED TO BE 16 GA AWM 105ºC UNLESS OTHERWISE SPECIFIED 14 GA AWM 105ºC 22 GA AWM 105ºC ...

Page 19: ...UFC 420 440 water filtration system 19 P N 1010908 Rev A 03 12 A J Antunes Co Notes ...

Page 20: ... operating and main tenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a ...

Reviews: