background image

STEAMER DISPLAY CABINET SDC-500

9

P/N 1010968 Rev. E 12/14

MAINTENANCE

CAUTION

Refer to the Important Safety Information section of this 

manual to review information on handling and cleaning 

this unit.

Figure 8. Draining Water from the Unit

Daily Draining and Cleaning

To ensure proper operation, the unit must be drained and 

cleaned at the end of each serving day.

  1.  Turn the power off, unplug the power cord, and allow 

the unit to completely cool. 

  2.  Place a bucket under the water tube.
  3.  Lift the Tube Lock (Figure 8). Rotate the Water Tube 

counterclockwise to drain the unit of water.

  4.  Return the Water Tube to an upright position. Lock the 

Tube with the Tube Lock.

  5.  Remove the Shelves and Diffuser. Wash them in hot, 

soapy water. Rinse and allow them to air dry.

  6.  Wash all glass surfaces inside and out with a clean, 

damp towel.

  7.  Wipe all metal surfaces of the unit with a clean, damp 

cloth and allow to air dry.

  6.  Re-install the Diffuser and Shelves. Return the unit into 

service.

NOTE: If the unit is not cleaned properly each day, per-

manent damage of the equipment finish and accessories 

may result. This damage is NOT covered by warranty.

LINE

PO

WER

LINE

x 4

LOCKED

Slide

Tube Lock

up to

Unlock

Tube Lock 

(Locked)

Rotate Water Tube 

down to empty water

from unit.

Figure 9. Replacing Light Bulbs

Replacing Light Bulbs

The SDC-500 is shipped with four compact fluorescent light 

bulbs installed to illuminate product. Follow these steps to 

access and replace the light bulbs.

Disconnect Power Before

Replacing. Use Only Fluorescent 

Lamp or Equivalent

Max Lamp 25W

WARNING

Turn the unit off and unplug the power cord before pro-

ceeding. Do NOT operate the unit without the Top Cover 

installed.

  1.  Turn the unit off, unplug the power cord, and allow the 

unit to cool.

  2.  Remove the 4 screws securing the Top Cover to the 

unit (Figure 9). Set these screws aside.

  3.  Remove the Top Cover and set aside. 

  4.  Replace bulbs as needed.

  5.  Re-attach the Top Cover and secure with the 4 screws 

removed in Step 2.

NOTE: Do NOT operate the unit without the Top Cover 

attached and secured with the 4 screws.

  6.  Plug in the power cord and turn the unit on.

NOTE: Use 25 watt medium base compact fluorescent 

bulbs. Incandescent bulbs can be used, however do NOT 

exceed 25 watts per bulb.

Summary of Contents for 9100532

Page 1: ...P N 1010968 Rev E 12 14 STEAMER DISPLAY CABINET Model SDC 500 Owner s Manual MANUFACTURING NUMBERS 9100532 9100533 9100534 A S D L I S T E CM O I N NIT A T C T I S L US E D ...

Page 2: ...ty Information Please read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are NOT covered under warranty The warranty does NOT extend to Damages caused in shipment or damage as result of...

Page 3: ...nd parts Failure to observe caution could result in personal injury Service Technical Assistance If you experience any problems with the installation or operation of your unit contact your local Roundup Authorized Service Agency Fill in the information below and have it handy when calling your authorized service agency for assistance The serial number is on the specification plate located on the u...

Page 4: ...with a vinegar solution In addition to the warnings and cautions in this manual use the following guidelines for safe operation of the unit Read all instructions before using equipment For your safety the equipment is furnished with a properly grounded cord connector Do NOT attempt to defeat the grounded connector Install or locate the equipment only for its intended use as described in this manua...

Page 5: ...o 9100533 9100534 100 F 165 F 38 C 74 C SPECIFICATIONS Electrical Ratings Plug Configuration Model Mfg No Volts Watts Amp Hz Plug Description Plug Configuration SDC 500 9100532 9100533 9100534 120 1750 14 6 50 60 NEMA 5 15P 15 Amp 120 Volt Non locking WHT BLK GRN A B C Model Mfg No Width A Depth B Height C Shipping Weight Operating Weight SDC 500 9100532 9100533 9100534 16 1 2 419 mm 17 3 4 451 mm...

Page 6: ...d outside of all glass surfaces with a hot damp cloth NOTE Do NOT use a dripping wet cloth Wring out before use 4 Install Diffuser and Shelves into unit Equipment Setup When placing the unit into service pay attention to the following guidelines Make sure power off and the unit is at room temperature Do NOT block or cover any openings on the unit Do NOT immerse cord or plug in water Keep cord away...

Page 7: ...re the proper distance apart for the food product Follow these steps if the shelf height needs adjustment 1 Turn the power off and allow it to cool to room temperature 2 Open the Front Door and if necessary remove any food product 3 Remove the shelves as needed refer below to the sec tion titled Removing Shelves 4 Lift up on the front portion of the desired Support Rack until it is free from the f...

Page 8: ...product into the unit and close the Front Door 5 Turn the unit on During the initial warm up period the unit will display the following sequence of codes a 8888 for one second b CH 1 for one second c The unit s Setpoint Temperature for one second d CH 1 for one second e The unit s Setpoint Temperature f The unit s actual cabinet temperature 6 To remove product from the unit open the Front Door and...

Page 9: ...ach day per manent damage of the equipment finish and accessories may result This damage is NOT covered by warranty LIN E PO WE R LIN E x 4 Slide Tube Lock up to Unlock Tube Lock Locked Rotate Water Tube down to empty water from unit Figure 9 Replacing Light Bulbs Replacing Light Bulbs The SDC 500 is shipped with four compact fluorescent light bulbs installed to illuminate product Follow these ste...

Page 10: ...console Note Press and hold the TEMP SCALE button for 2 3 seconds to toggle between displaying the temperature in Fahrenheit and Celsius HI flashes if the actual cabinet temperature exceeds 250 F 121 C NOTE The thermistor should be 100k ohm 2 at room temperature OPEN flashes if the thermistor is open or disconnected The unit will not call for heat NOTE The thermistor should be 100k ohms 2 at room ...

Page 11: ...r service Inoperable Control Board Inoperable Heater s Loose burnt broken wiring in circuit Display flashes HI and the cabinet does not heat up Inoperable Thermistor Contact your maintenance person or Authorized Service Agency for service Inoperable Control Board Display flashes HI and the cabinet is very hot Solid State Relay contacts shorted closed Contact your maintenance person or Authorized S...

Page 12: ...STEAMER DISPLAY CABINET SDC 500 12 P N 1010968 Rev E 12 14 REPLACEMENT PARTS 1 2 3 4 7 6 6 10 39 43 7 8 7 37 5 6 9 11 12 19 26 21 23 33 38 27 40 20 41 42 13 14 15 16 17 18 22 30 29 31 32 28 24 25 16 ...

Page 13: ...9 Drain Tube 875 OD x 1 5 Lg 1 22 0012121 Heat Sink Assembly 1 Item Part Description Qty No Item Part Description Qty No 23 7000369 Thermistor Kit 1 24 4010199 Transformer 120V 1 25 7000652 Solid State Relay Zero Cross 50A 1 26 7000344 Hi Limit Thermostat Kit 1 27 0505589 Drain Lock 1 28 210K230 Bumper Leg 1 Recess 4 29 3100136 Mach Screw 10 32 x 1 25 10 Pack 1 30 218P145 Bumper Leg Cover 10 Pack ...

Page 14: ...STEAMER DISPLAY CABINET SDC 500 14 P N 1010968 Rev E 12 14 NOTES ...

Page 15: ...STEAMER DISPLAY CABINET SDC 500 15 P N 1010968 Rev E 12 14 NOTES continued ...

Page 16: ...eding maximum weight capacity 4 lbs This warranty does not cover water contamination prob lems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service ag...