Installing Shelves

The Support Racks and Shelves are designed with a “notch 

and tab” system. The tabs on the Shelf drop into the notches 

in the Support Racks. When properly seated, the Shelf will 

slide in and out of the unit without detaching. 

  1.  Open the front door and insert the Shelf onto the 

desired Support Racks (Figure 4). 

NOTE: Insert the Shelves tab end first.

  2.  Slide the Shelf into the unit until the tabs drop into the 

slots at the back of the Support Racks. 

  3.  Move the Shelf in and out of the unit. If the Shelf can 

be pulled completely out of the unit, it is not correctly 

installed. Repeat these steps until each Shelf cannot be 

pulled directly out of the unit. 

Support 

Rack

Rear 

Corner 

Post

Front 

Corner 

Post

INSTALLATION (continued)

Figure 5. Adjusting Shelf Height

Adjusting Shelf Height

Inspect the Support Racks. They have been pre-installed in 

the unit. Ensure that they are the proper distance apart for 

the food product. Follow these steps if the shelf height needs 

adjustment:

  1.  Turn the power off and allow it to cool to room  

temperature.

  2.  Open the Front Door and, if necessary, remove any 

food product.

  3.  Remove the shelves as needed (refer below to the sec-

tion titled 

Removing Shelves

).

  4.  Lift up on the front portion of the desired Support Rack 

until it is free from the front Corner Post. Then, slide the 

Support Rack out of the rear Corner Post (Figure 5). 

Repeat this on the opposite Support Bracket.

  5.  Install the Support Rack at the new location by inserting 

the back end of the rack into the rear Corner Post and 

then sliding the front of the rack down onto the tab of 

the Front Corner Post (Figure 5).

LIN

E

PO

WER

LIN

E

Slide the Shelf along

the support until the

Shelf Tab drops down into 

the Slot in the Support.

Slot in

Support

Shelf Tab

Figure 4. Installing Shelf

Removing Shelves

To remove shelves from the unit:

  1.  Open the front door and remove any product.

  2.  While lifting upwards on the Shelf, slide it so that the 

tabs release from the Support Rack.

  3.  Pull the Shelf out and away from the unit.

Tab

Slot

Summary of Contents for 9100532

Page 1: ...P N 1010968 Rev E 12 14 STEAMER DISPLAY CABINET Model SDC 500 Owner s Manual MANUFACTURING NUMBERS 9100532 9100533 9100534 A S D L I S T E CM O I N NIT A T C T I S L US E D ...

Page 2: ...ty Information Please read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are NOT covered under warranty The warranty does NOT extend to Damages caused in shipment or damage as result of...

Page 3: ...nd parts Failure to observe caution could result in personal injury Service Technical Assistance If you experience any problems with the installation or operation of your unit contact your local Roundup Authorized Service Agency Fill in the information below and have it handy when calling your authorized service agency for assistance The serial number is on the specification plate located on the u...

Page 4: ...with a vinegar solution In addition to the warnings and cautions in this manual use the following guidelines for safe operation of the unit Read all instructions before using equipment For your safety the equipment is furnished with a properly grounded cord connector Do NOT attempt to defeat the grounded connector Install or locate the equipment only for its intended use as described in this manua...

Page 5: ...o 9100533 9100534 100 F 165 F 38 C 74 C SPECIFICATIONS Electrical Ratings Plug Configuration Model Mfg No Volts Watts Amp Hz Plug Description Plug Configuration SDC 500 9100532 9100533 9100534 120 1750 14 6 50 60 NEMA 5 15P 15 Amp 120 Volt Non locking WHT BLK GRN A B C Model Mfg No Width A Depth B Height C Shipping Weight Operating Weight SDC 500 9100532 9100533 9100534 16 1 2 419 mm 17 3 4 451 mm...

Page 6: ...d outside of all glass surfaces with a hot damp cloth NOTE Do NOT use a dripping wet cloth Wring out before use 4 Install Diffuser and Shelves into unit Equipment Setup When placing the unit into service pay attention to the following guidelines Make sure power off and the unit is at room temperature Do NOT block or cover any openings on the unit Do NOT immerse cord or plug in water Keep cord away...

Page 7: ...re the proper distance apart for the food product Follow these steps if the shelf height needs adjustment 1 Turn the power off and allow it to cool to room temperature 2 Open the Front Door and if necessary remove any food product 3 Remove the shelves as needed refer below to the sec tion titled Removing Shelves 4 Lift up on the front portion of the desired Support Rack until it is free from the f...

Page 8: ...product into the unit and close the Front Door 5 Turn the unit on During the initial warm up period the unit will display the following sequence of codes a 8888 for one second b CH 1 for one second c The unit s Setpoint Temperature for one second d CH 1 for one second e The unit s Setpoint Temperature f The unit s actual cabinet temperature 6 To remove product from the unit open the Front Door and...

Page 9: ...ach day per manent damage of the equipment finish and accessories may result This damage is NOT covered by warranty LIN E PO WE R LIN E x 4 Slide Tube Lock up to Unlock Tube Lock Locked Rotate Water Tube down to empty water from unit Figure 9 Replacing Light Bulbs Replacing Light Bulbs The SDC 500 is shipped with four compact fluorescent light bulbs installed to illuminate product Follow these ste...

Page 10: ...console Note Press and hold the TEMP SCALE button for 2 3 seconds to toggle between displaying the temperature in Fahrenheit and Celsius HI flashes if the actual cabinet temperature exceeds 250 F 121 C NOTE The thermistor should be 100k ohm 2 at room temperature OPEN flashes if the thermistor is open or disconnected The unit will not call for heat NOTE The thermistor should be 100k ohms 2 at room ...

Page 11: ...r service Inoperable Control Board Inoperable Heater s Loose burnt broken wiring in circuit Display flashes HI and the cabinet does not heat up Inoperable Thermistor Contact your maintenance person or Authorized Service Agency for service Inoperable Control Board Display flashes HI and the cabinet is very hot Solid State Relay contacts shorted closed Contact your maintenance person or Authorized S...

Page 12: ...STEAMER DISPLAY CABINET SDC 500 12 P N 1010968 Rev E 12 14 REPLACEMENT PARTS 1 2 3 4 7 6 6 10 39 43 7 8 7 37 5 6 9 11 12 19 26 21 23 33 38 27 40 20 41 42 13 14 15 16 17 18 22 30 29 31 32 28 24 25 16 ...

Page 13: ...9 Drain Tube 875 OD x 1 5 Lg 1 22 0012121 Heat Sink Assembly 1 Item Part Description Qty No Item Part Description Qty No 23 7000369 Thermistor Kit 1 24 4010199 Transformer 120V 1 25 7000652 Solid State Relay Zero Cross 50A 1 26 7000344 Hi Limit Thermostat Kit 1 27 0505589 Drain Lock 1 28 210K230 Bumper Leg 1 Recess 4 29 3100136 Mach Screw 10 32 x 1 25 10 Pack 1 30 218P145 Bumper Leg Cover 10 Pack ...

Page 14: ...STEAMER DISPLAY CABINET SDC 500 14 P N 1010968 Rev E 12 14 NOTES ...

Page 15: ...STEAMER DISPLAY CABINET SDC 500 15 P N 1010968 Rev E 12 14 NOTES continued ...

Page 16: ...eding maximum weight capacity 4 lbs This warranty does not cover water contamination prob lems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service ag...

Reviews: