background image

Carefully read these instructions for using the fireplace insert and keep the manual in a 
safe place. A.caminetti fireplace inserts are certifed according to European standard EN 
13229 and  carry the CE indication. When assembling the fireplace insert, you must comply 
with local regulations and instructions applicable to national and European standards. To
 ensure  that your freplace operates correctly, the fireplace must be builded by a 
specialized company.

1.2.  Risk of burning

   

Do not leave children near the fireplace insert unsupervise

d.

1.3.  Safe distance

- The door, handle and glass are hot when in operation – there is risk of burning!

As a protection against fying sparks on flammable types of floors (carpet, 
wooden floor, cork, etc.) there must be used a fire-proof layer (ceramics, stone, 
glass or metal) with minimum dimensions (see Fig. 1). The distance is measured 
from the glass in the fireplace insert.

Always close the door even when fireplace is cold and only open it when 

starting fre,  adding wood or cleaning the insert.

All the surfaces of fireplace insert are very hot when in operation. For 
servicing, use the attached glove and:

In the area where the fire is visible there is direct heat radiating, the minimum 
distance of 80 
cm from flammable items must be kept (flammable parts of the construction, 
wood, furniture, decorative textile, carpets, curtains, etc.). Outside the area of 
visibility of the fire, there must be a minimum distance of 20 cm from fammable 
materials (flammable parts of the construction, wood, furniture, decorative 
textile, carpets, curtains, etc.). The distance is measured from the glass in the 
fireplace insert (Fig. 1).

1 .  SAFETY

04

1.1.  Safety instructions

FIG.1

Summary of Contents for Crystal 3D 50/60

Page 1: ...Manual of use installation operation www acaminetti factory com...

Page 2: ...ck metall Schott ROBAX Culimeta Skamol Insert coat made of quality steel in accordance with EN 13229 Insert components manufactured using modern cnc machines 2D Laser and press brakes Insert welded wi...

Page 3: ...pes of wood 06 2 4 Storage of wood fuel 07 2 5 Recommended dose of fuel 3 DESCRIPTION OF CONTROL ELEMENTS 3 1 Description of control elements 08 3 2 Options for closing the door 4 OPERATION OF FREPLAC...

Page 4: ...TS 15 10 CHECKING THE PRODUCT 16 11 CORRECT POSITIONING OF THE FIREPLACE 12 TRANSPORT 17 13 POSITIONING THE FIREPLACE INSERT 18 14 REMOVING THE TRANSPORT SECURING 19 15 GAS OUTLET VARIANTS 20 16 CONNE...

Page 5: ...re must be used a fire proof layer ceramics stone glass or metal with minimum dimensions see Fig 1 The distance is measured from the glass in the fireplace insert Always close the door even when firep...

Page 6: ...low those rules 05 1 6 FIRE IN THE CHIMNEY When burning wood sparks from the fireplace may get into the chimney and ignite the built up layer of soot Therefore the fireplace insert smoke flue and the...

Page 7: ...air supply into the freplace insert must not be modifed 2 FUEL It is forbidden to interfere with the construction of freplace insert If any unauthorized technical modifcations are made the manufacture...

Page 8: ...insert and rapidly shortens its service life In the case of repeated burning of wet wood the insert or parts of the insert can be damaged This will also block the chimney and increase the risk of fire...

Page 9: ...closing 1 if you want the door to automatically close inform your freplace builder before starting construction 3 1 DESCRIPTION OF CONTROL ELEMENTS 1 handles for opening the door for cleaning 2 handl...

Page 10: ...F AIR SUPPLY 4 OPERATION OF FIREPLACE INSERTS 1 Set the handle for regulation of the air supply for burning to the maximum This ensure a sufficient supply of air for ignition 09 4 Close the door and o...

Page 11: ...of the collected gases with the oxygen 10 Note In all the models the opening of air supply is when it is marked number 1 the closing of air supply is when it is marked number 0 4 2 OPERATION IN THE TR...

Page 12: ...iftdoor first open all the handles along the perimeter Fig 10a Then open the door into the cleaning position 11 FIG 10A FIG 10B Only clean the glass with a wet paper cloth If this is insufficient appl...

Page 13: ...combustion air is not opened the line for the external air supply is blocked contact your fireplace technician the draught of the chimney is insufficient in the transient period Smoke escapes into the...

Page 14: ...warranty does not apply to damage originated during transport due to incorrect storage in a wet environment The warranty does not apply to common wearing of the freplace insert The warranty does not a...

Page 15: ...the warranty period For the replaceable parts the warranty period stated by law is valid To make a warranty claim contact your freplace technician and submit warranty certifcate description and photo...

Page 16: ...KW 0 031 3 4 kg h 87 CRYSTAL 110 MAX 18 KW 0 028 3 4 kg h 88 QUATTRO 80 MAX 13 KW 0 036 2 3 kg h 89 QUATTRO 90 MAX 14 KW 0 033 2 3 kg h 87 QUATTRO 100 MAX 17 KW 0 045 3 4 kg h 85 FLAT Premium 60x50 13...

Page 17: ...supply must be ensured in the room Burning 1 kg of the wood requires approximately 12 m3 of air There must not be any electric cables running through the wall or ceiling where the fireplace insert wil...

Page 18: ...ng the transport handles which can be inserted into the on the body of the fireplace insert Fig 1 Before transporting make sure that both the ejection mechanism of the doors applicable to fireplace in...

Page 19: ...foundation plate not on an unstable or movable surface 12 POSITIONING THE FIREPLACE INSERT The distance of the fireplace insert from the floor can be regulated by turning the legs Use the adjustable l...

Page 20: ...of the door If there are any defects inform your supplier and stop the installation work After positioning the fireplace insert remove the transport securings that prevent damage to the lift down doo...

Page 21: ...ded for connection to the accumulating flue system or for direct connection to the chimney 20 Hot air system for distributing in home Pipe for smoke connection in some models the diameter is fi 200mm...

Page 22: ...tandards The correct operation of the chimney according to dIn En 13384 must be signed by legal authority When making the chimney calculations you must include the parameters of the freplace insert Wh...

Page 23: ...moment that you have take out the cover part in the front side of the fireplace which is marked the logo A caminetti FIG 3 chapter 13 in the same time you have to take out the condraweight covering wh...

Page 24: ...FLAT LIFTDOOR MODELS CORNER LIFTDOOR MODELS 24 NOTE THE DOOR OPENING IS THE SAME FOR ALL CRYSTAL MODELS CRYSTAL MODELS...

Page 25: ...ning fire safety options for using materials and the size of the ventilation grids The construction must enable access for cleaning the consumer appliance chimney flue and chimney Figures 17a and 17b...

Page 26: ...ea must be clean and resistant to the abrasion low of convection air from the hot air jacket All hot convectional piping must consist of form stable non flammable materials When installing a hot air j...

Page 27: ...place insert and the surroundings as well as the bearing frame and the surroundings sealing tape or insulating paper must be inserted to covers the difference in the heat expansion of the material ent...

Page 28: ...of 40 cm Area outside the radiation There must be a minimum gap of 5 cm between the wall of the surroundings and items from flammable materials The semi area to the surroundings must be open to preven...

Page 29: ...aim at adding significant value to our partners customers and to the environment By implementing our unique systems benefits such as energy savings enhanced performance improved working and living en...

Page 30: ...A caminetti factory National road km2 Korce Erseke KORCE ALBANIA info acaminetti factory com www acaminetti factory com A caminettti GmbH AM Industriegleis 6a Ergolding Germany...

Reviews: