Once a year, before starting the heating season, the fireplace insert should be inspected by
an expert - fireplace technician. This maintenance should include:
checking the sealing parts and mechanism for opening
the door of the fireplace insert
5.
3
.
rEGular SPECialiST MaiNTENaNCE
checking and cleaning of the burning chamber
and burnt passages
for hot-air fireplace insert:
-
-
checking the regulation and air supply system
12
6. WHAT TO DO IN THE CASE OF A DEFECT
The glass is heavily smoked
Possible reasons:
- incorrect fuel is used
- regulation of the combustion air is not opened -
- the line for the external air supply is blocked (contact your fireplace technician)
- the draught of the chimney is insufficient - in the transient period.
The fire does not want to ignite and keeps on going out
Possible reasons:
- incorrect fuel is used
- regulation of the combustion air is not opened -
- the line for the external air supply is blocked (contact your fireplace technician)
- the draught of the chimney is insufficient - in the transient period.
Smoke escapes into the room when wood is added
Possible reasons:
- incorrect fuel is used
- the draught in the chimney is insufficient – in the transient period
- the door was opened too fast
- fuel was not added in the correct phase of burning
- the door sealing is damaged (contact your fireplace technician
The wood burns too quickly or the consumption of the wood is too high
Possible reasons:
- incorrect fuel was used
- recommended dose of the fuel was not kept
- the air supply for burning did not reduce
- the door is not completely closed
The cooling loop often switches off
Possible reasons:
- the recommended dose of the fuel is not kept
- there is a high temperature of the accumulation tank – stop and add wood
- the valve is damaged (contact your fireplace technician)
- there was an electricity breakdown – stop to add wood
If defects continue, contact your fireplace technician!!