A and T Labs
K6 Audio Power Amplifier Assembly Manual
2001 A and T Labs Inc.
AMK6a
11
3.2.2 Capacitors:
ü
Part Value
ü
Part Value
ü
Part
Value
C1
2200uf 200V
C10 4700pf
C19
470UF 100V
C2
2200uf 200V
C11 4700pf
C20
470UF 100V
C3
1000uf 50V
C12 4700pf
C21
.01UF
C4
1000uf 50v
C13 4700pf
C22
.22uf
C5
.001uf
C14 560pf 500V
C23
.01UF
C6
10uf 50V
C15 Not used
C24
3300PF
C7
100pf
C16 Not used
C25
.22UF
C8
.01uf
C17 470UF 100V
C26
1000uf 25v
C9
10uf 50V
C18 470UF 100V
3.2.3 Diodes, ICs, Q5, and REG1:
(Power rectifier diodes, power transistors and REG2 are installed later after heat sink
installation)
ü
Part
Type
ü
Part
Type
ü
Part
Type
D5
1N4002
D10
1N4735A
IC1
SG3525
D6
1N4002
D11
1N4002
IC2
LM358
D7
1N4002
D12
1N4735A
IC3
LM358
D8
1N4002
D13
1N4742A
Q5
VN0610LL
D9
1N4742A
D14
1N4735A
REG1
7812
Install the transformers and current transformer, inductors, ZNR1, TR1, LEDs, bridge
rectifiers, and the fuse holders. The current transformer T3 is installed with two turns of
insulated 16 gage wire wound through the hole in the transformer and soldered into the
large holes adjacent to T3. Also wire the voltage select switch at this time.
This is the time for determining your power supply jumper configuration: For 120v
operation, equip jumpers 1, 2, and 3. For 240 v operation, use jumper 4 only.
3.2.4 Transformers and miscellaneous parts
ü
Part
ü
Part
ü
Part
Description
ü
Part
Description
T1
Fuse clips (6)
L1
350uH
TR1
KC022L-ND
T2
Term. Blocks(10)
L2
350uH
LED1 Red
T3
Voltage select Switch
L3
1.8UH x 2
LED2 Green
T4
Wire for T3
ZNR1
ERZ-V20D431
F2
.25 amp fuse
F1
15 amp fuse
F3
8 amp fuse
Jumpers 1-4
BR1
Bridge rectifier
DB2
Bridge rectifier