SIO (totalizing):
To test the totalizing function you will need 2 scales (one is the scale under test)
and a totalizing cable.
Put the scale under test into the master position, and the other scale in the
second position on the cable.
Scale under test
Slave
Leave any other cable
Disconnected
Figure 10 SIO Master Test
Turn both scales on. Wait until both scale go to a stable zero display. Insure that both
scales are in the totalizing mode, look for the bar next to TOT on the display. Press the
local/total key to turn on the bar if needed. Apply a load to the master scale. The same
weight should appear on the slave scale. If this test fails try pressing the print key.
The receiver must sense an open line condition to force a scale to become the master
scale. Pressing print will force an output anyway. This is useful in isolating between
an input and an output failure.