GigaSync block diagram 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
The  block  diagram  highlights  the  presence  of  three  major  structures:  a  CPU  ensures  the  correct 
operation of all the basic electronics operation and carries out the voltage and current measurements 
(

), the other CPU manages the User Interface (

), and finally the power components isolated from the 

rest of the logic (

). The four power INPUTs, each applicable via two redundant connectors, are isolated 

from each other and do not apply any conversion to the voltage applied to the cartridges, in this way it 
is possible to simultaneously connect different voltages and different polarities (e.g.: INPUT 1 

à

 48V, 

INPUT 2 

à

 24V, INPUT 3 

à

 -48V). 

 

Voltage range, power consumption and maximum load

 

 

Input Voltage 

Self Consumption 

Max Load 

PoE 

36-57 V DC 

4.5W 

na 

MAIN INPUT 

18-60 V DC 

4.5W 

na 

INPUT 1 

18-60 V DC 

 

0.3W 

600W 

INPUT 2 

18-60 V DC 

 

0.3W 

600W 

INPUT 3 

18-60 V DC 

 

0.3W 

600W 

 
 
The cartridges power INPUTs are equipped with reverse polarity protection: in case of wrong connection, 
the corresponding cartridge is not receiving power. 
The two CPUs are powered by an isolated converter. In this way it is guaranteed maximum immunity 
against electrical faults on the supply lines of the cartridges. 
 

 

*   Functions available only on PoE-CS Cartridge. 
**  Functions available only on PoE and PoE-CS Cartridge.

 

 

MAIN INPUT POWER 

INPUT POWER 1 

INPUT POWER 2 

INPUT POWER 3 

isolated 

DCDC CONVERTER 

CPU 

UI 

CPU 

HW 

SYNC 

Inverse Polarity 

PROTECTION 

Inverse Polarity 

PROTECTION 

 

Inverse Polarity 

PROTECTION 

 

VOLTAGE & LOAD 

MEASUREMENT 

VOLTAGE & LOAD 

MEASUREMENT 

VOLTAGE & LOAD 

MEASUREMENT 

ON / OFF 

PROTECTION 

ON / OFF 

PROTECTION 

ON / OFF 

PROTECTION 

SYNC PULSE 

GENERATION * 

SYNC PULSE 

GENERATION * 

SYNC PULSE 

GENERATION * 

 KEY DETECT ** 

 OUTPUT PORTS 

Wifi 

 KEY DETECT ** 

 OUTPUT PORTS 

 OUTPUT PORTS 

 KEY DETECT ** 

Cartridge 1 

Cartridge 2 

Cartridge 3 

ETH PoE 

DUAL CPU 

 SYNC IN SYNC OUT 

 LEDs OPT 

GPS 

LE

D

 

LE

D

 

LE

D

 

Summary of Contents for GIGASYNC V2

Page 1: ... range pag 3 connectors scheme pag 4 ethernet pinout sync in and sync out pag 4 LED legend pag 4 OPT functions pag 4 1 2 Cartridges pag 5 how they look pag 5 comparative table pag 6 LED legend pag 6 9 KEY pag 6 1 3 Installation pag 7 1 4 Software update pag 8 1 5 WEB Interface pag 9 1 6 Command Line Interface pag 13 ...

Page 2: ...etal cover and inserting the cartridge No fixing screws are required On the back there are power input terminals of the Base Unit and their cartridges Each power input is independent insulated and equipped with reverse polarity protection The voltage range is 18 60 Volts The Base Unit can also be powered by PoE IEEE 802 3af standard via the Ethernet There are also ports for the SYNC IN and SYNC OU...

Page 3: ...DC 0 3W 600W INPUT 2 18 60 V DC 0 3W 600W INPUT 3 18 60 V DC 0 3W 600W The cartridges power INPUTs are equipped with reverse polarity protection in case of wrong connection the corresponding cartridge is not receiving power The two CPUs are powered by an isolated converter In this way it is guaranteed maximum immunity against electrical faults on the supply lines of the cartridges Functions availa...

Page 4: ...cription SYNC flashing green 500ms flashing green 200ms alternating with the LED ALARM boot phase not complete pulse presence on the selected Sync synchronization GPS or SYNC IN STATUS blue device correctly powered ALARM flashing red 500ms when pressing the OPT button alternating with the LED SYNC boot phase not complete Button functions OPT OPT long press Description WiFi on off ALARM LED starts ...

Page 5: ... CS cartridges are also able to inject the sync pulse On each port of all the cartridges a hardware protection against short circuit is active and there are dual stages TVS and GDT surge arresters on each line GS G PoE GS G PoE CS LAN Ports GS G TER PoE Ports STATUS LEDs KEY SLOTS MAIN CONNECTOR MAIN CONNECTOR FRONT VIEW SIDE VIEW BACK VIEW BACK VIEW SIDE VIEW FRONT VIEW Terminals STATUS LEDs ...

Page 6: ...on the cartridge connector flashing white on a port blink identification red flashing disabled port red 9 KEY inserted incorrectly or invalid flashing purple 9 KEY missing violet power cycle 10 seconds green enabled port light blue port enabled with Canopy Sync synchronization blue port enabled with Cambium Sync synchronization Part Number GS K 9 S GS K AB GS KB GS K BRP Name on KEY 9 SYNC A B B B...

Page 7: ...able to connect to ground the rack cabinet and connect the grounding terminal on the back To install the cartridges just remove the metal plate placed at slot cover on the Base Unit and insert the cartridge making sure it entirely fits No fixing screws for the cartridges are required the connector provides sufficient strength to prevent that they do not inadvertently fall To remove the cartridge p...

Page 8: ...upload the update file in the Controller Actions System Update of the web interface 1 4 2 Upload Upload the update file update_ version number 9dt 1 4 3 Update Using your login credentials to GigaSync ex admin password connect via SSH and run the command system upgrade upgrade or via web interface in the section Actions Controller System Update GigaSync automatically validate the update installati...

Page 9: ...rm and disabled state The graphs of voltage and load values are real time updated and turn yellow and red in the presence of deviations from the mean Figure 1 LOGIN PAGE IP 192 168 9 1 Login admin Password password Figure 2 MAIN PAGE Once the login the main screen is divided into two blocks The gray part concerns the Base Unit the part below lists the connected cartridges The line of each cartridg...

Page 10: ...etwork settings turn on WiFi and enable NAT that enables surfing the Internet when connected to WiFi GigaSync if the GigaSync network parameters allow it In SYNC tab it is possible to select the sync source whose presence is indicated by the green circle It is possible also to enable the Sync Cascade and feed the Sync IN port for the direct supply of a uGPS LOG tab displays the events Figure 4 PRO...

Page 11: ...wer the loads applied also during this phase Figure 6 CARTRIDGES For each cartridge type is displayed the input voltage the temperature and the total load and related graphics Expanding the cartridge menu it is possible to turn on and off every port and get information on alarms For PoE cartridges they are indicated the type of 9 KEY and the presence and type of sync pulse For every port the comma...

Page 12: ...s defined for the web interface With the TAB key you can view the complete menu and typing the command Figure 2 SOFTWARE UPDATE The System section contains all the commands to administer the Base Unit and verify the status of services It is also possible to check the status of integrity of the update packages and perform the update ...

Reviews: