![4B WDA3V34C Operation Manual Download Page 12](http://html1.mh-extra.com/html/4b/wda3v34c/wda3v34c_operation-manual_3069635012.webp)
NORMAL RUNNING
Plastic Elevator Bucket
PULSE
PULSE
BELT MISALIGNMENT
Plastic Elevator Bucket
PULSE
NO PULSE
Figure 6 -
WDA Sensor Placement For Plastic Elevator
Buckets (Detecting Bolts) On Up Side Of Leg
1/2 in.
to
1 in.
Plastic Elevator Bucket
Approximately
1-1/2 inches
Bolt Head
Elevator
Trunking
WDA
Mounting
Block
WDA Sensor
Potentiometer Sensing Range
Adjustment Screw
Figure 7 -
WDA Sensor Installation
For Plastic Buckets
If using stainless steel
bolts (non-ferrous), use
PTFE coated steel fender
washers (ferrous) between
the belt and bucket.
PAGE 12