3.  SELECT A QUALIFIED AND COMPETENT INSTALLER

Correct installation of the product is important for safety and performance.  If you have not asked 4B to 

perform the installation of the unit on your behalf, it is critical for the safety of your operation and those 

who may perform work on your operation that you select a qualified and competent electrical installer to 

undertake the installation.  The product must be installed properly to perform its designed functions.  The 

installer should be qualified, trained, and competent to perform the installation in accordance with local 

and national electrical codes, all relevant regulations, as well as any of your own standards and preventive 

maintenance  requirements,  and  other  product  installation  information  supplied  with  the  product.    You 

should be prepared to provide the installer with all necessary installation information to assist in the 

installation.

4.  ESTABLISH AND FOLLOW A REGULAR MAINTENANCE AND INSPECTION SCHEDULE FOR 

YOUR 4B PRODUCTS

You should develop a proper maintenance and inspection program to confirm that your system is in good 

working order at all times.  You will be in the best position to determine the appropriate frequency for 

inspection.  Many different factors known to the user will assist you in deciding the frequency of inspection.  

These factors may include but are not limited to weather conditions; construction work at the facility; hours 

of operation; animal or insect infestation; and the real-world experience of knowing how your employees 

perform their jobs.  The personnel or person you select to install, operate, maintain, inspect or perform 

any work whatsoever, should be trained and qualified to perform these important functions.  Complete 

and accurate records of the maintenance and inspection process should be created and retained by you 

at all times.

5.  RETAIN AND REFER TO THE OPERATION MANUAL FOR 4B’S SUGGESTED MAINTENANCE 

AND INSPECTION RECOMMENDATIONS

As  all  operations  are  different,  please  understand  that  your  specific  operation  may  require  additional 

adjustments in the maintenance and inspection process essential to permit the monitoring device to 

perform its intended function.  Retain the Operation Manual and other important maintenance and service 

documents  provided  by  4B  and  have  them  readily  available  for  people  servicing  your  4B  equipment.  

Should you have any questions, please call go to www.go4b.com or call the 24-hour hotline at +1-309-

698-5611.

6.  SERVICE REQUEST

If you have questions or comments about the operation of your unit or require the unit to be serviced 

please contact the 4B location who supplied the product or send your request go to www.go4b.com or call 

the 24-hour hotline at +1-309-698-5611.  Please have available product part numbers, serial numbers, 

and approximate date of installation.  In order to assist you, after the product has been placed into service, 

complete the online product registration section which is accessed via our website www.go4b.com.

Summary of Contents for RG1V4A

Page 1: ...www go4b com RG1 ROTARY LEVEL INDICATOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s RG1V56A RG1V4A...

Page 2: ......

Page 3: ...CT OVERVIEW Page 6 SPECIFICATIONS Page 6 DIMENSIONS Page 6 INSTALLATION Page 7 STANDARD WIRING DIAGRAM Page 8 TESTING AND COMMISSIONING Page 10 TROUBLESHOOTING GUIDE Page 10 PARTS AND ACCESSORIES Page...

Page 4: ...esponsibility of the user unless you have asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to...

Page 5: ...ction work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install...

Page 6: ...any inlet or outlet to close down or start up When the level of the material reaches normal levels again the motor returns to its initial position and restarts SPECIFICATIONS Power Supply RG1V56A 110...

Page 7: ...and side Figure 1 The level gauge is mounted on silos or vessels on the side or top It is important to choose the position so that the device is outside of the product flow likewise taking care that t...

Page 8: ...the cable entry It is realised via M5 screw and eyelet cable crimp The external earthing has to be carried out by the installer The equipment has to be protected against impact and electrostatic insid...

Page 9: ...PAGE 9 Figure 4 110 240 VAC Wiring detail Figure 5 24 VDC Wiring detail...

Page 10: ...lutely forbidden for children unauthorized and or inexperienced persons to touch or use the level gauge Make sure that the electricity system complies with the laws in force Make sure that the earthin...

Page 11: ...w in NYLON 120 x 100 mm RG1SP3 3 Vanes NYLON screw 120 x 65 mm RG1SP1 SS Single vane screw in Stainless steel 120 x 100 mm RG1SP4 SS 4 Vanes Stainless steel screw 100 x 60 mm RG1SP4 SS L 4 Vanes Stain...

Page 12: ...ss steel extension without rod guard 1000 mm 1 m long RG1EXT 1500 SS Stainless steel extension without rod guard 1500 mm 1 5 m long RG1EXT 0500 SS G Extension with rod guard in stainless steel 500 mm...

Page 13: ...aluminium flange External diameter 203 mm holes centers 178 mm 6 equidistant 7 5 holes RG1 TUBE 2 5 Iron sleeve 2 1 2 BSPP Gas RG1 TUBE 2 5 SS Stainless steel sleeve 2 1 2 BSPP Gas SPARES RG1MOTOR SPA...

Page 14: ...teel 120 x 100 mm SUGGESTED MATERIAL DENSITY kg dm3 between 0 6 and 0 9 MIN INSTALLATION HOLE DIMENSION mm 65 For medium weight materials RG1SP4 SS 4 Vanes Stainless steel screw 100 x 60 mm SUGGESTED...

Page 15: ...SUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE ALTHOUGH...

Page 16: ...rlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue Morton IL 61550 USA Tel 309 698 5611 Fax 309 698 5615 4B BRAIME COMPONENT...

Reviews: