TESTING AND COMMISSIONING

1.  Follow the safety rules below when installing this product.

2.  Check that the unit is correctly installed (see standard wiring diagram). 

WARNING

All the appropriate safety precautions must be taken when electrically operated equipment is used, in 

order to reduce the risk of fire outbreaks, electric shock and injuries to persons.

- Keep the work zone clean and orderly. Accidents are more likely to occur in untidy areas and 

environments.

- Before beginning work, make sure that the level gauge is in a perfect condition. Damaged or broken 

parts must be repaired or replaced by competent personnel authorized by the Manufacturer.

- All verifications, inspections, cleaning and maintenance operations, part changes and replacements, 

must be carried out with the level gauge disconnected and the plug removed from the power socket.

- It is absolutely forbidden for children, unauthorized and/or inexperienced persons to touch or use the 

level gauge.

- Make sure that the electricity system complies with the laws in force. Make sure that the earthing is 

efficiently connected when the instrument is installed.

Make sure that the power socket is suitable, that it complies with the laws in force and that it has a built-

in automatic protection circuit-breaker. The level

gauge must never be stopped by detaching the plug; moreover, never use the cable to pull the plug 

from the socket.

- Periodically check to be sure that the cable is in perfect conditions and replace it if damaged. This 

operation must only be carried out by competent and

authorized persons. Only use extension cables of the permitted type and marked.

- Do not allow children or unauthorized persons to touch the cable when the instrument is plugged in.

- The models with signal lamp must be protected from direct exposure to sunlight.

TROUBLESHOOTING GUIDE

FAULT

REMEDY

Paddle is not rotating

Check power supply.

Manufactured by: CamLogic Snc, 42025, IT

Summary of Contents for RG1V4A

Page 1: ...www go4b com RG1 ROTARY LEVEL INDICATOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s RG1V56A RG1V4A...

Page 2: ......

Page 3: ...CT OVERVIEW Page 6 SPECIFICATIONS Page 6 DIMENSIONS Page 6 INSTALLATION Page 7 STANDARD WIRING DIAGRAM Page 8 TESTING AND COMMISSIONING Page 10 TROUBLESHOOTING GUIDE Page 10 PARTS AND ACCESSORIES Page...

Page 4: ...esponsibility of the user unless you have asked 4B to perform these tasks B All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to...

Page 5: ...ction work at the facility hours of operation animal or insect infestation and the real world experience of knowing how your employees perform their jobs The personnel or person you select to install...

Page 6: ...any inlet or outlet to close down or start up When the level of the material reaches normal levels again the motor returns to its initial position and restarts SPECIFICATIONS Power Supply RG1V56A 110...

Page 7: ...and side Figure 1 The level gauge is mounted on silos or vessels on the side or top It is important to choose the position so that the device is outside of the product flow likewise taking care that t...

Page 8: ...the cable entry It is realised via M5 screw and eyelet cable crimp The external earthing has to be carried out by the installer The equipment has to be protected against impact and electrostatic insid...

Page 9: ...PAGE 9 Figure 4 110 240 VAC Wiring detail Figure 5 24 VDC Wiring detail...

Page 10: ...lutely forbidden for children unauthorized and or inexperienced persons to touch or use the level gauge Make sure that the electricity system complies with the laws in force Make sure that the earthin...

Page 11: ...w in NYLON 120 x 100 mm RG1SP3 3 Vanes NYLON screw 120 x 65 mm RG1SP1 SS Single vane screw in Stainless steel 120 x 100 mm RG1SP4 SS 4 Vanes Stainless steel screw 100 x 60 mm RG1SP4 SS L 4 Vanes Stain...

Page 12: ...ss steel extension without rod guard 1000 mm 1 m long RG1EXT 1500 SS Stainless steel extension without rod guard 1500 mm 1 5 m long RG1EXT 0500 SS G Extension with rod guard in stainless steel 500 mm...

Page 13: ...aluminium flange External diameter 203 mm holes centers 178 mm 6 equidistant 7 5 holes RG1 TUBE 2 5 Iron sleeve 2 1 2 BSPP Gas RG1 TUBE 2 5 SS Stainless steel sleeve 2 1 2 BSPP Gas SPARES RG1MOTOR SPA...

Page 14: ...teel 120 x 100 mm SUGGESTED MATERIAL DENSITY kg dm3 between 0 6 and 0 9 MIN INSTALLATION HOLE DIMENSION mm 65 For medium weight materials RG1SP4 SS 4 Vanes Stainless steel screw 100 x 60 mm SUGGESTED...

Page 15: ...SUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE ALTHOUGH...

Page 16: ...rlord Place Acacia Ridge Queensland 4110 Australia Tel 61 0 7 3711 2565 Fax 61 0 7 3711 2574 4B COMPONENTS LTD 625 Erie Avenue Morton IL 61550 USA Tel 309 698 5611 Fax 309 698 5615 4B BRAIME COMPONENT...

Reviews: