6
Power Dissipation in Watts
ATEX category 2D: 12 Watts
ATEX category 3D: 25 Watts
CSA (F5004NV4CAI-PGW): 12 Watts
CSA (F5004NV46CAI-PGW): 12 Watts
Approval Safety Information
To Open the Lid:
1.
Disconnect power (isolate ALL circuits)
2.
Untighten the lid securing screws
3.
Carefully open the lid ensuring that the gasket is not damaged and remains in place
To Close the Lid:
1.
Check that the gasket is correctly fitted into the box groove and is undamaged.
2.
Tighten the lid screws.
3.
Check that the lid and box are correctly mated.
Special conditions of use:
1.
The equipment shall be suitably earth bonded via the PCB mounted earth
terminal inside the equipment enclosure.
2.
Warning: The equipment is a potential static hazard, clean only with a damp
cloth.
3.
Do not allow dust layers to build up on the equipment.