
K-METRON Radio User Instructions (Firmware 3.0.4; Doc v4.0)
5 |
P a g e
2.5
Loss of Magnetic Coupling.
When magnetic couple of the cube magnet is lost it can be retrieved by retaining the end of
the attached cord and fishing the magnet out of the opening. If the spherical magnet loses
coupling, then it must be retrieved by turning the moulding upside down and allowing the
magnet to fall out or by using a telescopic metal pointer to grab it.
2.6
Tracking the Sensor Head to the Point of Measurement.
The calibrated magnet will automatically couple, orientate and centre itself over the Sensor
Head. Once coupled track the Sensor Head to the point on the part which you wish to
measure, taking care not to remove the sensor head from the face of the work piece. This
may result in the loss of the magnetic coupling. The calibrated magnet will follow the Sensor
Head to the desired point of measurement.
2.7
Inserting the Sensor Head in the Dock.
If the sensor head is difficult to engage in the Sensor Head Dock, then a thin film of grease
should be applied to the O-ring found within the Sensor Head Dock.
2.8
Visual Display Terminology
Displayed Text
Meaning
N/M
No Magnet in range
O/R
Out of Range
Mag type: Cube
Selected Magnet: 10mm Cube
Mag type: Sphere
Selected Magnet: 10mm Sphere
Mag type: 10-30mm
Selected Magnet: 19mm Sphere
PWR OFF
In automatic Power Off Mode