SHIPPING UNITS
Questions? Email: [email protected] | Call: 800-995-6329
3
OPERATING CONDITIONS
ASSEMBLY – INSTALLATION PIPES
Check the shipment to
ensure all items ordered
have been received. Note
any missing items or
damages to 475 ASAP and
include photos if possible.
Contact: [email protected]
e
2
:
Installation pipe, exterior
white grill, heat exchange unit,
indoor cover, optional
condensate ring, and
installation instructions are
supplied as a complete set.
e
2
short:
Installation pipe,
exterior white grill, heat
exchanger unit, indoor cover,
optional condensate ring, and
installation instructions are
supplied as a complete set.
Indoor Cover
Heat Exchange Unit
Outside Grill
Installation Pipe
Make the wall openings for the assembly pipes
(e.g. by coring, core bit Ø 6.37"/162mm).
If necessary, shorten the pipe to the desired
installation length
e
2
minimum 11.8"(300 mm):
e
2
short minimum 8" (200 mm)
.
Take care that the pipe extends on both sides for
finishes (sheetrock plaster, siding) with finishes
Installed flush with the pipe.
Insert the pipe, with a min. 3/8:12 (3mm) pitch
and airseal it with ROFLEX 150 gaskets,
TESCON tapes or other airtight solutions.