background image

Controller

Connector to Connector Options

Cable P/N Options

Cable Description

Where Used

To Controller

To Drives / 

Backplane

3ware 9690SA SAS/SATA RAID Controllers

9690SA-8I

SFF-8087

SFF-8087

CBL-SFF8087-05M

0.5 meter cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s 

Multi-lane SFF-8087 connector(s)

CBL-SFF8087-06M

0.6 meter cable

SFF-8087

SFF-8482

CBL-SAS8087OCF-06M

0.6 meter forward breakout cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four 

individual SAS or SATA drives; includes individual drive power connectors

SFF-8087

Discrete

CBL-SFF8087OCF-05M

0.5 meter forward breakout cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to  

the drives’ or backplane’s discrete SATA connector(s)

CBL-SFF8087OCF-06M

0.6 meter forward breakout cable

CBL-SFF8087OCF-10M

1.0 meter forward breakout cable

9690SA-8E

SFF-8088

SFF-8088

CBL-SFF8088SAS-10M

1.0 meter cable

Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s 

Multi-lane SFF-8088 connector(s)

CBL-SFF8088SAS-20M

2.0 meter cable

SFF-8088

SFF-8470

CBL-SFF8088IB-10M

1.0 meter cable (converter cable)

Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s 

Multi-lane SFF-8470 connector(s)

CBL-SFF8088IB-20M

2.0 meter cable (converter cable)

9690SA-4I4E

SFF-8088

SFF-8088

CBL-SFF8088SAS-10M

1.0 meter cable

Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s 

Multi-lane SFF-8088 connector(s)

CBL-SFF8088SAS-20M

2.0 meter cable

SFF-8088

SFF-8470

CBL-SFF8088IB-10M

1.0 meter cable (converter cable)

Connects the controller’s SFF-8088 Multi-lane connector(s) to the enclosure’s 

Multi-lane SFF-8470 connector(s)

CBL-SFF8088IB-20M

2.0 meter cable (converter cable)

SFF-8087

SFF-8087

CBL-SFF8087-05M

0.5 meter cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s 

Multi-lane SFF-8087 connector(s)

CBL-SFF8087-06M

0.6 meter cable

SFF-8087

SFF-8482

CBL-SAS8087OCF-06M

0.6 meter forward breakout cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four 

individual SAS or SATA drives; includes individual drive power connectors

9690SA-4I

SFF-8087

SFF-8087

CBL-SFF8087-05M

0.5 meter cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to the backplane’s 

Multi-lane SFF-8087 connector(s)

CBL-SFF8087-06M

0.6 meter cable

SFF-8087

SFF-8482

CBL-SAS8087OCF-06M

0.6 meter forward breakout cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to up to four 

individual SAS or SATA drives; includes individual drive power connectors

SFF-8087

Discrete

CBL-SFF8087OCF-05M

0.5 meter forward breakout cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to  

the drives’ or backplane’s discrete SATA connector(s)

CBL-SFF8087OCF-06M

0.6 meter forward breakout cable

CBL-SFF8087OCF-10M

1.0 meter forward breakout cable

3ware Controller/Cable Matrix

6

3ware 9650SE Internal RAID Controllers

9650SE-2LP

Discrete

Discrete 

CBL-SATA-39

39” (1m) standard, discrete, point-to-point SATA cable

Connects a controller’s discrete SATA port(s) to the drives’  

or backplane’s discrete SATA connector(s)

9650SE-4LPML, 

-8LPML, -12ML, 

-16ML

SFF-8087

SFF-8087

CBL-SFF8087-05M

0.5 meter cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to  

the backplane’s SFF-8087 Multi-lane connector(s)

CBL-SFF8087-06M

0.6 meter cable

SFF-8087

Discrete

CBL-SFF8087OCF-05M

0.5 meter forward breakout cable

Connects the controller’s SFF-8087 Multi-lane connector(s) to  

the drives’ or backplane’s discrete SATA connector(s)

CBL-SFF8087OCF-06M

0.6 meter forward breakout cable

CBL-SFF8087OCF-10M

1.0 meter forward breakout cable

SFF-8087

SFF-8470

CBL-SFF8087IB-05M

0.5 meter converter cable (internal hybrid)

Connects the controller’s SFF-8087 Multi-lane (ML) connector(s)  

to the backplane’s SFF-8470 Multi-lane (MI) connector(s)

CBL-SFF8087IB-06M

0.6 meter converter cable (internal hybrid)

9650SE-24M8

M8

SFF-8087

CBL-M8ML-06M

0.6 meter “Y” cable

Connects the controller’s M8 Multi-lane connector(s) to the 

backplane’s SFF-8087 Multi-lane connector(s)

M8

Discrete

CBL-M8OCF-06M

0.6 meter forward breakout cable

Connects the controller’s M8 Multi-lane connector(s) to the drives’ 

discrete SATA connectors 

CBL-M8OCF-10M

1.0 meter forward breakout cable

Summary of Contents for RAID Controllers

Page 1: ...st 3ware product information visit www 3ware com AMCC is a registered trademark of Applied Micro Circuits Corporation 3ware 3DM and StorSwitch are registered trademarks of Applied Micro Circuits Corporation in the United States All other trademarks are the property of their respective holders Copyright 2008 Applied Micro Circuits Corporation All Rights Reserved FamPG_102108 215 Moffett Park Drive ...

Page 2: ... Random Performance Emerging Infrastructure The cost and performance optimized interface for the majority of value end storage appliances that employ a fixed number of drives to serve vertical applications like video surveillance Vertical Applications Cost Optimized Optimized for Sequential Performance Mature Infrastructure AMCC Headquarters in Sunnyvale CA Ta b l e o f C o n t e n t s 3ware RAID ...

Page 3: ...ernal 8 External 4 Internal 4 External 4 Internal Drive Interface SAS and SATA SAS and SATA SAS and SATA SAS and SATA PCI Express x8 x8 x8 x8 RAID Levels 0 1 5 6 10 50 Single Disk 0 1 5 6 10 50 Single Disk 0 1 5 6 10 50 Single Disk 0 1 5 6 10 50 Single Disk Onboard Memory 512MB DDR2 533 512MB DDR2 533 512MB DDR2 533 512MB DDR2 533 ConnectorType and Quantity 2X SFF 8087 mini SAS 2X SFF 8088 mini SA...

Page 4: ...ne Multi lane Multi lane BBU Support No Yes Yes Yes Yes Yes Yes SATA 3ware 9550SXU High Performance PCI X to Serial ATA II RAID Controllers High Performance PCI X RAID Solution of Choice The 3ware 9550SXU SATA II RAID controller delivers performance robust fault tolerance and multi terabyte capacities Combined with an advanced RAID management feature set that includes web based command based and A...

Page 5: ...d SAS and or SATA traffic through a single cable Increased system reliability Reduced cable count Streamlined storage Locked connections Improved airflow 5 Breakout cables have a Multi lane connector on one end and discrete connectors on the other end Forward breakout cables have a Multi lane connector on the controller end and discrete connectors to the drives Reverse breakout cables have discret...

Page 6: ...controller s SFF 8087 Multi lane connector s to up to four individual SAS or SATA drives includes individual drive power connectors 9690SA 4I SFF 8087 SFF 8087 CBL SFF8087 05M 0 5 meter cable Connects the controller s SFF 8087 Multi lane connector s to the backplane s Multi lane SFF 8087 connector s CBL SFF8087 06M 0 6 meter cable SFF 8087 SFF 8482 CBL SAS8087OCF 06M 0 6 meter forward breakout cab...

Page 7: ...or s to the backplane s SFF 8087 Multi lane connector s CBL SFF8087 06M 0 6 meter cable SFF 8087 Discrete CBL SFF8087OCF 05M 0 5 meter forward breakout cable Connects the controller s SFF 8087 Multi lane connector s to the drives or backplane s discrete SATA connector s CBL SFF8087OCF 10M 1 0 meter forward breakout cable SFF 8087 SFF 8470 CBL SFF8087IB 05M 0 5 meter converter cable internal hybrid...

Page 8: ...cess DMA channels Performance StorSave Powerful reliability enhancements Achieves unmatched data protection while maximizing performance in critical RAID modes when data availability accessibility and data protection are most needed Data Protection StreamFusion Intelligent cache algorithm Maximizes application performance under heavy loads by dynamically allocating controller cache for maximum ban...

Page 9: ...tem WinXP SP2 HDS7222525VLSA80 fw V36OA60A 64KB stripes RAID 5 all other settings at default Streams AMCC Competition 1 Competition 2 StreamFusion in Action 9 Common RAID Levels RAID 0 1 5 10 and JBOD Block 10 Block 7 Block 4 P1 Parity Disk 1 Block 11 Block 8 P2 Parity Q1 Parity Disk 2 Block 12 P3 Parity Q2 Parity Block 1 Disk 3 Q4 Parity Block 9 Block 6 Block 3 Disk 5 Striped Data with Distribute...

Page 10: ...Ports RAID Levels Controller Connector Footprint RoHS 9650SE 2LP PCI Express x1 2 0 1 Single Disk JBOD Discrete Low profile 6 6 9650SE 4LPML PCI Express x4 4 0 1 5 10 Single Disk JBOD Multi lane SFF 8087 Low profile 6 6 9650SE 4LPME PCI Express x4 4 0 1 5 10 JBOD Multi lane SFF 8088 Low profile 6 6 9650SE 8LPML PCI Express x4 8 0 1 5 6 10 50 Single Disk JBOD Multi lane SFF 8087 Low profile 6 6 965...

Page 11: ...ies Model Number Description BBU MODULE 03 Battery Backup Unit for 3ware 9650SE 9590SE 9550SX U BBU MODULE 04 Battery Backup Unit for 3ware 9690SA 9650SE 9590SE 9550SX U Includes remote battery mounting kit BATT SPARE 02 Replacement battery for BBU MODULE 03 and BBU MODULE 04 BBU 9500S 01 Battery Backup Unit for 3ware 9500S BATT 9500S SPARE Replacement battery for BBU 9500S 01 RDC 400 SATA SATA in...

Reviews: