22
A
S
II
Us
ers
G
ui
d
e
|
1/
24
/2
0
19
Factory Program for SMF28
The AS II comes standard with 1 factory program that is designed for SMF28.
Parameter
Value
Mode
0
# of Windows
1
Heater Temp
920
Strip Tension
3.5
Zero Mov't Length
1
Prooftest Tension
10
ProofTest Speed
2
Clamp Delay
200
Prooftest hold time
0
Preheat time
3000
Readjust tension off/on
0
Air on position
0
Strip Start position
0
Strip End Position
20
Fiber up position
0
Air off position
0
Vacuum pre delay
500
Air pre delay
50
Start Speed
15
Strip Speed
20
Ramp Time
20
Air post delay
0
Vacuum post delay
2000